Napoleon Fireplaces TORCH GT8P User Manual

Browse online or download User Manual for Fireplaces Napoleon Fireplaces TORCH GT8P. Napoleon Fireplaces TORCH GT8P User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
W415-0619 / A / 08.09.07
INSTALLATION AND
OPERATION INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada (705)721-1212 fax(705)722-6031
www.napoleonreplaces.com [email protected]
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE.
GT8N
NATURAL GAS
GT8P
PROPANE
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of
life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
SAFETY INFORMATION
Certified for Canadian and United States using ANSI/CSA Methods.
W415-0619 / A / 08.09.07
$10.00
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - OPERATION INSTRUCTIONS

1W415-0619 / A / 08.09.07INSTALLATION ANDOPERATION INSTRUCTIONSWolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)

Page 2 - TABLE of CONTENTS

10W415-0619 / A /08.09.07FRAME INSTALLATION1. Align the two holes in the upper portion of the hinge on the control door assembly to those in the bott

Page 3 - CONDITIONS AND LIMITATIONS

11W415-0619 / A / 08.09.07A. This fi replace is equipped with an ignition device which automatically lights the burner. Do not try to ligh

Page 4 - GENERAL INFORMATION

12W415-0619 / A /08.09.07Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more

Page 5 - VENTING LENGTHS

13W415-0619 / A / 08.09.07# PART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET3* W010-1736 DOOR LATCH ASSEMBLY 4 W010-1743

Page 6 - FIGURE 3

14W415-0619 / A /08.09.07TROUBLE SHOOTING GUIDEBEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE IGNITOR AND THE MAIN BURNER

Page 7 - INSTALLATION / FRAMING

15W415-0619 / A / 08.09.07Fireplace Service HistoryThis fireplace must be serviced annually depending on usageDATEDEALER NAMESERVICE TECHNICIAN NAMES

Page 8 - GAS INSTALLATION

16W415-0619 / A /08.09.07NOTES

Page 9 - ELECTRICAL CONNECTION

2W415-0619 / A /08.09.07 PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Gla

Page 10 - FINISHING

3W415-0619 / A / 08.09.07ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS

Page 11 - OPERATING INSTRUCTIONS

4W415-0619 / A /08.09.07163/4Minimum clearance to combustible construction from fi replace and vent surfaces:Fireplace framing: - 6” to top - 0” t

Page 12 - MAINTENANCE

5W415-0619 / A / 08.09.07WARNINGDO NOT SUBSTITUTE MATERIALS. USE CARE WHEN HANDLING GLASS COMPONENTS DO NOT STIKE, OR SLAM SHUT. DO NOT OPERATE WIT

Page 13 - REPLACEMENTS

6W415-0619 / A /08.09.07NBBGAFCHHLKJMFIGURE 3

Page 14 - TROUBLE SHOOTING GUIDE

7W415-0619 / A / 08.09.07INSTALLATION / FRAMINGWALL AND CEILING PROTECTIONThis application occurs when venting through an exterior wall. Having deter

Page 15 - Fireplace Service History

8W415-0619 / A /08.09.07The has been designed to be installed mid-way up an outside wall. When installing this unit close to the fi n

Page 16 - W415-0619 / A /08.09.07

9W415-0619 / A / 08.09.07MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:Fireplace framing - 6” to top - 0” to stand-offs (rear and sides) Fi

Comments to this Manuals