1
W415-0847 / C / 04.11.12
SAFETY INFORMATION
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
- This is an unvented gas- red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
section “ COMBUSTION AND VENTILATION AIR
PROVISIONS”.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.33A
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • [email protected]
!
WARNING
If the information in these instructions are
not followed exactly, a re or explosion
may result causing property damage,
personal injury or loss of life.
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.
$10.00
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2B, VOLUME II FOR UNVENTED ROOM HEATERS.
GVFT8N
NATURAL GAS
GVFT8P
PROPANE
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - OPERATING INSTRUCTIONS

1W415-0847 / C / 04.11.12SAFETY INFORMATION- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other a

Page 2 - TABLE OF CONTENTS

10W415-0847 / C / 04.11.1230.1AInstallation and servicing to be done by a qualifi ed installer.A. Move the appliance into position and secure.B. If

Page 3 - 1.0 INSTALLATION OVERVIEW

11W415-0847 / C / 04.11.12Outlet pressure can be checked to ensure it is measuring 3.5” W.C. (NG) or 10.0” W.C. (LP).A. Outlet pressure can be checke

Page 4 - 2.0 INTRODUCTION

12W415-0847 / C / 04.11.12MINIMUM CLEARANCES TO COMBUSTIBLES:- 18” to top- 1” to sides- 8” to bottom- 0” to rear (cabinet)- 1/2” to rear (applian

Page 5 - 2.2 GENERAL INSTRUCTIONS

13W415-0847 / C / 04.11.12243KEYHOLEINSTALLATIONTEMPLATETORCHMOUNTINGFRAMECABINET1MOUNTINGBRACKETDEFLECTORA. Using the installation template (W122-04

Page 6

14W415-0847 / C / 04.11.125.2 DOOR REMOVALBOTTOM DOOR RETAINERTOP DOOR FLANGEHITCH PINThe door is held in place at the bottom by a retainer tab that i

Page 7 - 2.4 RATING PLATE INFORMATION

15W415-0847 / C / 04.11.125.3 FRAME INSTALLATIONCONTROL DOORBOTTOMTRIM BRACKETW385-0479W385-0479A. Align the two holes in the upper portion of the

Page 8 - 3.0 INSTALLATION

16W415-0847 / C / 04.11.121/4” (APPROX.)CONTROLDOOR1/4”(APPROX.)LOGOWith the control door closed, affi x the logo to the front face of the control door

Page 9

17W415-0847 / C / 04.11.12A. Turn off the electrical and gas supply to the appliance.B. Remove the frame from the appliance by removing the 2 stainl

Page 10 - 3.3 GAS INSTALLATION

18W415-0847 / C / 04.11.12L1L2CABLECONNECTORELECTRICAL BOX(C/W GROUND SCREW)ELECTRICALBOX COVER(C/W 2 RECEPTACLES)GROUNDWIRE NUTSGROUND SCREW6.0 ELECT

Page 11 - 3.4 GAS PRESSURE

19W415-0847 / C / 04.11.127.0 OPERATIONIf appliance shuts off, do not relight until you provide fresh air. If appliance keeps shutting off, have it se

Page 12 - 4.0 FRAMING

2W415-0847 / C / 04.11.12NOTE: Changes, other than editorial, are denoted by a line in the margin.TABLE OF CONTENTS1.0 INSTALLATION OVERVIEW 32.0 INT

Page 13 - 5.0 FINISHING

20W415-0847 / C / 04.11.128.0 ADJUSTMENTS8.1 VENTURI ADJUSTMENTThis model has an air shutter that has been factory set open according to the chart bel

Page 14 - 5.2 DOOR REMOVAL

21W415-0847 / C / 04.11.129.0 MAINTENANCETURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.CAUTION: Label all wires prior to discon

Page 15 - 5.3 FRAME INSTALLATION

22W415-0847 / C / 04.11.12!WARNINGDO NOT USE SUBSTITUTE MATERIALS.GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.CARE MUST BE TAKEN WHEN REMOVING A

Page 16 - 5.4 LOGO PLACEMENT

23W415-0847 / C / 04.11.1210.0 REPLACEMENTSContact your dealer or the factory for questions concerning prices and policies on replacement parts. Norma

Page 17

24W415-0847 / C / 04.11.12ACCESSORIESREF PART NO. DESCRIPTION21 TMCSS MOUNTING CABINET22 TFSSO FRAME KIT23* LK8 LIGHT KIT2221

Page 18 - 6.0 ELECTRICAL INFORMATION

25W415-0847 / C / 04.11.1211.0 TROUBLESHOOTINGSYMPTOM PROBLEM TEST SOLUTIONFlame length consistently too large or too small. Carboning occurs.Unit is

Page 19 - 7.0 OPERATION

26W415-0847 / C / 04.11.12NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is n

Page 20 - SHUTTER

27W415-0847 / C / 04.11.1213.0 SERVICE HISTORY43.1

Page 21 - 9.0 MAINTENANCE

28W415-0847 / C / 04.11.1244.114.0 NOTES

Page 22 - 9.3 DOOR GLASS REPLACEMENT

3W415-0847 / C / 04.11.121.0 INSTALLATION OVERVIEWMounting cabinet, see “MOUNTING CABINET INSTALLATION” section.Frame, see “FRAME INSTALLATION” sectio

Page 23 - 10.0 REPLACEMENTS

4W415-0847 / C / 04.11.122.0 INTRODUCTION3.4B!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO

Page 24 - ACCESSORIES

5W415-0847 / C / 04.11.122.1 DIMENSIONS11/1649GAS LINE ACCESSELECTRICAL ACCESS3/8361/219/16715132.2 GENERAL INSTRUCTIONS!WARNINGCARBON MONOXIDE POISON

Page 25 - 11.0 TROUBLESHOOTING

6W415-0847 / C / 04.11.124.6AThis gas appliance should be installed and serviced by a qualifi ed installer to conform with local codes. Installation

Page 26 - 12.0 WARRANTY

7W415-0847 / C / 04.11.122.3 GENERAL INFORMATIONFOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION AND QUALITY! RATES

Page 27 - 13.0 SERVICE HISTORY

8W415-0847 / C / 04.11.123.0 INSTALLATION3.1 COMBUSTION AND VENTILATION AIR PROVISIONS17.1AThis appliance shall not be installed in a confi ned space

Page 28 - 14.0 NOTES

9W415-0847 / C / 04.11.1219.2EXAMPLE 1:In this example, because there is no door to the adjoining room, the volume of the adjoining room may be added