Napoleon Fireplaces GE38NT-M User Manual

Browse online or download User Manual for Fireplaces Napoleon Fireplaces GE38NT-M. Napoleon Fireplaces GE38NT-M User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
W415-0429 / C / 11.04.05
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com [email protected]
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS AND CSA 22.2 NO. 46 FOR ELECTRIC AIR HEATER.
NATURAL GAS MODEL
GE38NT-M
PROPANE GAS MODEL
GE38PT-M
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
COMBINATION ELECTRIC AND DIRECT VENT GAS FIREPLACE
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - DIRECT VENT MILLIVOLT SYSTEM

1W415-0429 / C / 11.04.05INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON

Page 2 - TABLE of CONTENTS

10W415-0429 / C / 11.04.05Example 4:V1=5 ftV2= 10 ftVT=V1 + V2 = 5 + 10 = 15 ftH1=1 ftH2=3 ftH3= 2.5 ftHR= H1 + H2 + H3 = 1 + 3 + 2.5 = 6.5 ftHO= .03(

Page 3

11W415-0429 / C / 11.04.05Formula 1: HT < 3VTFormula 2: HT + VT < 40 feetExample 5:V1=2 ftV2=1 ftV3= 1.5 ftSee graph to determine the required

Page 4 - GENERAL INFORMATION

12W415-0429 / C / 11.04.05FIGURE 15This application oc-curs when ventingthrough a roof. Installa-tion kits for various roofpitches are availablefrom y

Page 5 - VENTING LENGTHS

13W415-0429 / C / 11.04.05Use only approved aluminum flexi-ble liner kits marked:"Wolf Steel Approved Venting" as identified by thestamp o

Page 6 - AIR TERMINAL INSTALLATIONS

14W415-0429 / C / 11.04.05FIGURE 25The vent system must be supported approximately every 3feet for both vertical and horizontal runs. Use Wolf Steelve

Page 7 - SPECIAL VENT INSTALLATIONS

15W415-0429 / C / 11.04.05Proceed once the vent installation is complete.1. Move the fireplace into position and secure using thenailing tabs and/or s

Page 8 - DEFINITIONS

16W415-0429 / C / 11.04.0537 3/4"6"17 3/4"INSIDECHASE37 3/4"40 1/8"56 3/4"37 3/4"39 1/4"17 3/4"7"4&

Page 9

17W415-0429 / C / 11.04.05Lift up and remove the upperlouvres. Open the valve controldoor. Release the top and bot-tom door latches, located at therig

Page 10 - TOP EXIT VERTICAL TERMINATION

18W415-0429 / C / 11.04.054. Place the bottom of log #6 against the right side of thefirebox. The upper branch rests against log #1. The lowerbranch r

Page 11

19W415-0429 / C / 11.04.05FIGURE 467. Remove the flame effect panel by removing the 6 screws.8. Remove the flame generator by sliding to the left andd

Page 12 - WALL AND CEILING PROTECTION

2W415-0429 / C / 11.04.05WARNING• Do not burn wood or other materials in this fireplace.• Adults and especially children should be alerted to the haza

Page 13 - W415-0429 / C / 11.04.05

20W415-0429 / C / 11.04.051. Turns electric flame on/off.2. Turns gas flame on/off.3. Activates gas flame adjustment.4. Activates fan adjustment.5. Ad

Page 14 - USING RIGID VENT COMPONENTS

21W415-0429 / C / 11.04.05• Turn off all gas to the fireplace.• Open windows.• Do not try to light any appliance.• Do not touch any electric switch; d

Page 15

22W415-0429 / C / 11.04.05This fireplace requires 6 amps, 120 volt and a 60 hzgrounded circuit.Do NOT use the fireplace if any part has been underwate

Page 16 - NAILING TABS

23W415-0429 / B / 05.25.04Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow.Air shutters hav

Page 17 - FINISHING

24W415-0429 / C / 11.04.05GD220 (5 FT)# PART NO. DESCRIPTION37* W010-0397 4" FLEXIBLE ALUMINIUM LINER - (5 FT ) C/W SPACERS37* W410-0017 7"

Page 18 - GLOWING CRYSTAL EMBERS

25W415-0429 / C / 11.04.0548454446471213*161411552221396650516059ATTENTION-CHAUDCAUTION - HOT402AUTOON/OFFMANUALON/OFFFlameFanTimerClock24272826734516

Page 19 - BLOWER REPLACEMENT

26W415-0429 / C / 11.04.05Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.

Page 20 - OPERATION

27W415-0429 / C / 11.04.05Remote control - Dead batteries. - Make sure batteries are charged.not working - No power to the unit. - Make sure main powe

Page 21 - MAINTENANCE

28W415-0429 / C / 11.04.05Excessive noise - Flame generator motor is - Consult your local dealer.coming from the unit. faulty.Odour - Initial curing p

Page 22 - ELECTRICAL CONNECTION

3W415-0429 / C / 11.04.05ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS

Page 23 - ADJUSTMENTS

4W415-0429 / C / 11.04.05THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-ICED BY A QUALIFIED INSTALLER to conform with local codes.Installation pract

Page 24 - REPLACEMENTS

5W415-0429 / C / 11.04.05Use only Wolf Steel or Simpson Dura-Vent Model DV-GSventing components. Minimum and maximum vent lengths,for both horizontal

Page 25

6W415-0429 / C / 11.04.05AIR TERMINAL INSTALLATIONS***** Recommended to prevent condensation on windows and thermal breakage********** It is

Page 26 - TROUBLE SHOOTING GUIDE

7W415-0429 / C / 11.04.05Use the GD201 periscope kit to locate the air terminationabove grade. The periscope must be installed so that whenfinal gradi

Page 27 - ELECTRIC TROUBLE SHOOTING

8W415-0429 / C / 11.04.05for the following symbols used in the venting calcula-tions and examples are:> - greater than> - equal to or greater th

Page 28

9W415-0429 / C / 11.04.05H2H1V190°when (Ht) > (Vt)Simple venting configuration (only one90° elbow)See graph to determine the required ver-tical ris

Comments to this Manuals

No comments