1W415-0536 / C / 09.06.06W415-0536 / C / 09.06.06
10W415-0536 / C / 09.06.06FIGURE 12
11W415-0536 / C / 09.06.06This application occurs when venting through a roof. Installation kits for various roof pitches are available from your
12W415-0536 / C / 09.06.06
13W415-0536 / C / 09.06.06The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spa
14W415-0536 / C / 09.06.06FLUE COLLARRESTRICTOR PLATETOP OF THE FIREBOX
15W415-0536 / C / 09.06.06WARNINGFacing and/or finishing material must never overhang into the fireplace opening.Do not distort or force the frame kit
16W415-0536 / C / 09.06.06FIGURE 32MANTLE CLEARANCES03 4 78911131 2 5 671012HEIGHTMANTLEMANTLE WIDTHCombustible mantle clearance can vary according to
17W415-0536 / C / 09.06.064. Place log #4 with the charred branch facing inward. Position the pin in log #4 into the hole on the right of log #2.5.
18W415-0536 / C / 09.06.06BLOWERMOUNTINGPLATEREMOVE 4 SCREWSBLOWER REPLACEMENTThe Napoleon PARK AVENUE comes equipped with a heat circulating blower.
19W415-0536 / C / 09.06.061. Carefully remove the glass door and all logs. (Refer to the installation manual)2. Remove the two screws holding the
2W415-0536 / C / 09.06.06WHAT TO DO IF YOU SMELL GASDo not touch any electrical switch.If you cannot reach your gas supplier,call the fire department.
20W415-0536 / C / 09.06.061. Attach screw and spacer as illustrated in Fig. 46 to the bottom of both sides of the front housing.2. Attach the face p
21W415-0536 / C / 09.06.06REMOTE, RECEIvER AND vALvE ACCESS 1a. Rectangular Front Removal
22W415-0536 / C / 09.06.06running and the gas valve turned to the “ON” position. Ensure th
23W415-0536 / C / 09.06.065. FAN SPEED SETTINGThis function controls the speed of the hot air circulating fan. To change the fan speed, use the UP a
24W415-0536 / C / 09.06.06ADDRESS SETTING PROCEDUREUse the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock i
25W415-0536 / C / 09.06.06DIP SWITCH NUMBER (0 = ON / 1 = OFF)FIGURE 64
26W415-0536 / C / 09.06.06A. T lit by hand while following these instructions exactly.B. B
27W415-0536 / C / 09.06.06AIRSHUTTER OPENING lead to carboning. Opening the air sh
28W415-0536 / C / 09.06.06 This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther-moc
29W415-0536 / C / 09.06.0644435655531992221201823326268AUXON0:0000ON/OFFFEATURE SELECT6326242527363521311151412664950517134526756
3W415-0536 / C / 09.06.06 PG2-6 INTRODUCTION Warnings and Safety Precautions Warranty Dimensions General Instructions Gene
30W415-0536 / C / 09.06.06White / grey film forms.Sulphur from fuel is being deposited on glass, logs or combustion chamber sur-
31W415-0536 / C / 09.06.06Remote wall switch is in “OFF”main burner comes on when gas knob is turned to “ON” position.Wall switch is
32W415-0536 / C / 09.06.06Fireplace Service HistoryThis fireplace must be serviced annually depending on usageDATEDEALER NAMESERVICE TECHNICIAN NAMESE
33W415-0536 / C / 09.06.06NOTES
34W415-0536 / C / 09.06.06NOTES
4W415-0536 / C / 09.06.06ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS
5W415-0536 / C / 09.06.06 Minimum clearance t
6W415-0536 / C / 09.06.0624"16"8"Expansion / contraction nosies during heating up and cooling down cycles are normal and are to be expe
7W415-0536 / C / 09.06.06vertical rise in feetvTFIGURE 4when (HT) < (vT) (only one 90° elbow)See graph to determine the
8W415-0536 / C / 09.06.06H2H1v190°See graph to determine the required verti-cal rise VT for the required horizontal run HT.v1 = vT = 6 ft H1 = 3
9W415-0536 / C / 09.06.06required vertical rise in feetvT horizontal vent run Plus offset in feet HTwhen (HT) < (vT)FIGURE 9