1W415-0100 / D / 01.13.04INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.Wolf Steel Ltd., 24 Napoleon Rd., Barrie, O
10W415-0100 / D / 01.13.046. If more than one length of liner needs to be used toreach the fireplace, couple them together as illustrated.Seal the j
11W415-0100 / D / 01.13.04Where possible, cover the sides and top edges of the flash-ing with roofing material.6. Apply a heavy bead ofweatherproof
12W415-0100 / D / 01.13.04FIGURE 22The vent system must be supported approximately every 3feet for both vertical and horizontal runs. Use Wolf Stee
13W415-0100 / D / 01.13.04Combustible materials may be installed flush with the frontof the fireplace but must not cover any of the black face-areas
14W415-0100 / D / 01.13.044. Install rigid black pipe, 1/2" type-L copper tubing or, iflocal codes permit, a 3/8" flex connector and shut
15W415-0100 / D / 01.13.04PHAZERTM logs, exclusive to Napoleon Fireplaces, pro-vide a unique and realistic glowing effect that is different inevery
16W415-0100 / D / 01.13.04(To open the door, the trim must be removed.) Whenopening the fire viewing door, a simple procedure must befollowed in or
17W415-0100 / D / 01.13.04INSTALLATION TO BE DONE BY A QUALIFIED IN-STALLER and must be electrically connected and groundedin accordance with local
18W415-0100 / D / 01.13.04ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-FIED INSTALLER and must be connected and groundedin accordance with local co
19W415-0100 / D / 01.13.04• Turn off all gas to the fireplace.• Open windows.• Do not try to light any appliance.• Do not touch any electric switch;
2W415-0100 / D / 01.13.04WARNING• Do not burn wood or other materials in this fireplace.• Adults and especially children should be alerted to the ha
20W415-0100 / D / 01.13.04Natural gas models have air shutters set at ¼ (.250") inchopen. Propane gas models have air shutters set at 3/8(.375
21W415-0100 / D / 01.13.04# PART NO. DESCRIPTION1 GL-618 LOG SET COMPLETE2 W135-0097 EMBER/FRONT BRICK (#8L)3 W135-0098 EMBER/FRONT BRICK (#8R)4 W13
22W415-0100 / D / 01.13.04* WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only witha fast acting thermoco
23W415-0100 / D / 01.13.04Pilot goes out whenthe gas knob is re-leased.The gas valve has aninterlock devicewhich will not allowthe pilot burner to b
24W415-0100 / D / 01.13.04Exhaust fumessmelled in room,headaches.Fireplace is spilling.- check door seal and relief flap seal.- check for chimney bl
3W415-0100 / D / 01.13.04NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognizedISO 9001 : 2000 Quality Assurance
4W415-0100 / D / 01.13.04FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEENTEST-FIRED TO ASSURE ITS OPERATION AND QUAL-ITY! Maximum input is 45,000 BTU
5W415-0100 / D / 01.13.04FIGURE 3• Under extreme vent configurations, allow several min-utes (5-15) for the flame to stabilize after ignition.• Eigh
6W415-0100 / D / 01.13.04FIGURES 540 FT MAX1 FT MIN 8 FT MAX(1 FT MAX)HORIZONTAL VENT RUNin feetVERTICALRISE in feetHORIZONTAL VENT RUNin feetVERTIC
7W415-0100 / D / 01.13.04FIGURES 8HORIZONTAL VENT RUNin feetCOMBINEDVERTICALRISE in feetCOMBINED HORIZON-TAL VENT RUN in feetVERTICALRISE in feetFIG
8W415-0100 / D / 01.13.04AIR TERMINAL INSTALLATIONS***** Recommended to prevent condensation on windows and thermal breakage********** It is recomme
9W415-0100 / D / 01.13.04FIGURE 12This application occurs when vent-ing through an exterior wall.Having determined the air termi-nal location, cut a