1W415-0275 / C / 09.23.05R-2000CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLA
10W415-0275 / C / 09.23.05Attach the connectors fromthe black and white wiresto the thermodisc and se-cure the thermodiscbracket to the securingstud a
11W415-0275 / C / 09.23.05RECEPTACLE /JUNCTION BOXOPTIONAL THERMOSTATIC SENSOR SLOTSOPEN ENDEDBRACKETVARIABLE SPEED/PIEZO IGNITORJUNCTION BOXTHERMODIS
12W415-0275 / C / 09.23.05FLAME ADJUSTMENTKNOBOTPILLOIHTPILONOFFOPILOT ON/OFFKNOB• Turn off all gas to the fireplace.• Open windows.• Do not try to li
13W415-0275 / C / 09.23.05AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY AQUALIFIED GAS INSTALLER!Air shutter is accessed beside gas valve.PIPIPILOT SCRE
14W415-0275 / C / 09.23.05# PART NO. DESCRIPTION1 W357-0001 PIEZO IGNITER2 W680-0004 THERMOPILE3 W680-0005 THERMOCOUPLE4 W010-0764 BURNER5 W010-0800 N
15W415-0275 / C / 09.23.05
16W415-0275 / C / 09.23.05Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.
17W415-0275 / C / 09.23.05PIABPILOTNOLOTHILOFFOWhite / grey filmforms.Sulphur from fuel is beingdeposited on glass, logs orcombustion chamber sur-face
18W415-0275 / C / 09.23.05Wolf Steel Fireplace Service HistoryThis fireplace must be serviced annually depending on usage.DateService Technician NameS
19W415-0275 / C / 09.23.05NOTES
2W415-0275 / C / 09.23.05WARNING• The product is a vented gas fireplace. Do not burn wood or other materials in this fireplace.• Adults and especially
20W415-0275 / C / 09.23.05NOTES
3W415-0275 / C / 09.23.05NAPOLEON products are manufactured under the strict Standard of the world recognizedISO 9001 : 2000 Quality Assurance Certifi
4W415-0275 / C / 09.23.05Minimum inlet gas supply pressure is 4.5 inches watercolumn for natural gas and 11 inches water column forpropane. Maximum in
5W415-0275 / C / 09.23.05This is a vented appliance and must be connected to achimney in accordance with the current installation codes.In absence of
6W415-0275 / C / 09.23.05PIPILOT312NOLOTHILOFFOIt is best to frame your fireplace after it is positioned andthe vent system is installed. Use 2x4&apos
7W415-0275 / C / 09.23.05Combustible mantle clearance can vary according to themantle depth. Use the graph to help evaluate the clear-ance needed.FIGU
8W415-0275 / C / 09.23.05The upper louvres must beremoved to allow the doorto be opened or closed. Toaccess the lower doorlatch, open the valve con-t
9W415-0275 / C / 09.23.054. Position the notch located on the end of the center log(#5) against the middle grate post with the other end of thelog res
Comments to this Manuals