Napoleon-fireplaces STARfire 70 - GD70 User Manual

Browse online or download User Manual for Kiln Napoleon-fireplaces STARfire 70 - GD70. Napoleon Fireplaces STARfire 70 - GD70 Manuel d'utilisation

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
W415-0434 / G / 08.08.11
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • [email protected]
1.28C
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GD70NT-S
NATURAL GAS
GD70PT-S
PROPANE
Page view 0
1 2 3 4 5 6 ... 99 100

Summary of Contents

Page 1 - GD70PT-S

1W415-0434 / G / 08.08.11INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE CHILDREN OR O

Page 2 - TABLE OF CONTENTS

10W415-0434 / G / 08.08.1145.63.2 TYPICAL VENT INSTALLATION13 3/4” MIN36” 24” MAXIMUM49 3/4” MINIMUMPLUS RISE** See “VENTING” section3 FEETMINIMUM40

Page 3 - 1.0 INSTALLATION OVERVIEW

1W415-0434 / E /11.19.11INSTALLATEUR : LAISSEZ CE MANUEL AVEC L’APPAREIL. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.NE LAISSEZ P

Page 4 - 2.0 INTRODUCTION

11W415-0434 / G / 08.08.113.3 SPECIAL VENT INSTALLATION3.3.1 PERISCOPE TERMINATIONUse the periscope kit to locate the air termination above grade. Th

Page 5 - 2.2 GENERAL INSTRUCTIONS

12W415-0434 / G / 08.08.11INSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck or balcony.B 12” Δ9” ΔClearance to windows or

Page 6 - 2.3 GENERAL INFORMATION

13W415-0434 / G / 08.08.113.5 VENTING APPLICATION FLOW CHART13.1Horizontal TerminationVertical TerminationVertical rise is equal to or greater than t

Page 7 - 2.4 RATING PLATE INFORMATION

14W415-0434 / G / 08.08.113.8 TOP EXIT HORIZONTAL TERMINATION16.1ASimple venting confi guration (only one 90° elbow)(HT) < (VT)For vent confi gurati

Page 8 - 3.0 VENTING

15W415-0434 / G / 08.08.11(HT) > (VT) Simple venting configuration (only one 90° elbow)See graph to determine the required vertical rise VT for the

Page 9

16W415-0434 / G / 08.08.113.9 VERTICAL TERMINATION(HT) < (VT) Simple venting configurations.See graph to determine the required vertical rise VT fo

Page 10

17W415-0434 / G / 08.08.11(HT) > (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horizonta

Page 11 - 3.3.1 PERISCOPE TERMINATION

18W415-0434 / G / 08.08.114.0 INSTALLATION4.1 WALL AND CEILING PROTECTIONFor clearances to combustible materials from the vent pipe, see “FRAMING” se

Page 12 - 3.4 VENT TERMINAL CLEARANCES

19W415-0434 / G / 08.08.114.1.1 HORIZONTAL SHIELDINGThis application occurs when venting through an exterior wall. Having determined the correct heigh

Page 13 - 3.7 ELBOW VENT LENGTH VALUES

2W415-0434 / G / 08.08.11TABLE OF CONTENTS1.0 INSTALLATION OVERVIEW 32.0 INTRODUCTION 42.1 DIMENSIONS 52.2 GENERAL INSTRUCTIONS 52.3 GENERAL INFOR

Page 14

20W415-0434 / G / 08.08.114.2 USING FLEXIBLE VENT COMPONENTSFor safe and proper operation of the appliance, follow the venting instructions exactly.A

Page 15 - ) > (V

21W415-0434 / G / 08.08.114.2.2 VERTICAL AIR TERMINAL INSTALLATIONA. Fasten the roof support to the roof using the screws provided. The roof support

Page 16 - ) < (V

22W415-0434 / G / 08.08.114.2.3 APPLIANCE VENT CONNECTIONA. Install the inner fl ex pipe to the appliance. Secure with 3 screws and fl at washers. Seal

Page 17

23W415-0434 / G / 08.08.114.3.2 VERTICAL AIR TERMINAL INSTALLATIONA. Move the appliance into position.B. Fasten the roof support to the roof using t

Page 18 - 4.0 INSTALLATION

24W415-0434 / G / 08.08.114.4 GAS INSTALLATION30.1AInstallation and servicing to be done by a qualifi ed installer.A. Move the appliance into positi

Page 19 - 4.1.2 VERTICAL SHIELDING

25W415-0434 / G / 08.08.114.5 OPTIONAL WALL SWITCH / THERMOSTATFor ease of accessibility, an optional remote wall switch or millivolt thermostat may

Page 20

26W415-0434 / G / 08.08.115.0 FRAMING!WARNINGRISK OF FIRE!IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT

Page 21 - ROOF SUPPORT

27W415-0434 / G / 08.08.11* The top header must be steel. The sides studs must be steel.** The fi rst 10 inches of fi nishing material above the applian

Page 22

28W415-0434 / G / 08.08.11!WARNINGUSE ONLY NON-COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD, CERAMIC TILE, MARBLE, ETC. WHEN FINISHING THE APPLIANCE. DO

Page 23

29W415-0434 / G / 08.08.11Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed.Whe

Page 24 - 4.4 GAS INSTALLATION

3W415-0434 / G / 08.08.111.0 INSTALLATION OVERVIEWDoor, see “DOOR INSTALLATION” section.Louvre, see “LOUVRE INSTALLATION” section.Venting, see “VENTIN

Page 25 - 4.6 MOBILE HOME INSTALLATION

30W415-0434 / G / 08.08.116.0 FINISHING6.1 DOOR INSTALLATION!WARNINGRISK OF FIRE!NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE A

Page 26 - 5.0 FRAMING

31W415-0434 / G / 08.08.116.2 DOOR CLOSING AND OPENINGOpen the valve control door. Hook the top and bottom door latches, located at the right side of

Page 27 - OUTSIDE CHASE

32W415-0434 / G / 08.08.1115432A. Centre the two charcoal strips, as shown, along the inside front of the fi rebox. Place the rear log #1 onto the lo

Page 28 - 5.2 PROTRUDING FINISH

33W415-0434 / G / 08.08.116.7 CHARCOAL EMBERS6.8 GLOWING EMBERSGlowing embers (not supplied) maybe used to enhance the fl ame’s appearance.32.1Randomly

Page 29 - STAND OFF

34W415-0434 / G / 08.08.117.0 WIRING DIAGRAM / ELECTRICAL INFORMATION!WARNINGDO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIF

Page 30 - 6.0 FINISHING

35W415-0434 / G / 08.08.11Ensure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the appliance wi

Page 31 - 6.6 LOG PLACEMENT

36W415-0434 / G / 08.08.119.0 ADJUSTMENTS9.1 PILOT BURNER ADJUSTMENTAdjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direc

Page 32

37W415-0434 / G / 08.08.1177.1Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit may be restric

Page 33

38W415-0434 / G / 08.08.1110.0 MAINTENANCECAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper an

Page 34

39W415-0434 / G / 08.08.1110.1 NIGHT LIGHT REPLACEMENTYour appliance came equipped with our “NIGHT LIGHT”. The light has been pre-wired and can be co

Page 35 - 8.0 OPERATION

4W415-0434 / G / 08.08.112.0 INTRODUCTION3.1C!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO

Page 36 - 9.0 ADJUSTMENTS

40W415-0434 / G / 08.08.11This appliance comes equipped with a blower, a heat sensor, variable on/off speed control and a power cord.The blower is the

Page 37 - 9.3 FLAME CHARACTERISTICS

41W415-0434 / G / 08.08.1111.0 REPLACEMENTSContact your dealer or the factory for questions concerning prices and policies on replacement parts. Norma

Page 38 - MAINTENANCE

42W415-0434 / G / 08.08.11 COMPONENTSREF NO. PART NO. DESCRIPTION25* W290-0080 COVER PLATE GASKET26 W062-0005 BLOWER27 W690-0002 THERMODISC28* W750-00

Page 39 - 10.1 NIGHT LIGHT REPLACEMENT

43W415-0434 / G / 08.08.11ACCESSORIESREF NO. PART NO. DESCRIPTION49* W010-1777 FIRESTOP SPACER ASSEMBLY50* W500-0103 TERMINAL EXTENSION PLATE51 GD-301

Page 40 - 10.4 CARE OF GLASS

44W415-0434 / G / 08.08.1135373814**18135427231243426126651653641235292456741601536403969605117

Page 41 - 11.0 REPLACEMENTS

45W415-0434 / G / 08.08.1112.0 TROUBLE SHOOTINGSYMPTOM PROBLEM TEST SOLUTIONMain burner goes out; pilot stays on.Pilot fl ame is not large enough or no

Page 42 - VENT KITS

46W415-0434 / G / 08.08.11SYMPTOM PROBLEM TEST SOLUTIONPilot will not light. No spark at pilot burner. - Check if pilot can be lit by a match. - Chec

Page 43 - ACCESSORIES

47W415-0434 / G / 08.08.11NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is n

Page 44

48W415-0434 / G / 08.08.1114.0 SERVICE HISTORY43.1

Page 45 - 12.0 TROUBLE SHOOTING

52W415-0434 / E / 11.19.1144.1

Page 46 - SYMPTOM PROBLEM TEST SOLUTION

5W415-0434 / G / 08.08.112.1 DIMENSIONS2.2 GENERAL INSTRUCTIONSTHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform

Page 47 - CONDITIONS AND LIMITATIONS

51W415-0434 / E /11.19.1115.0 NOTES44.1

Page 48 - 14.0 SERVICE HISTORY

Date43.1Problèmes particuliersTravail effectuéNom du technicienDétaillantHistorique d’entretien Wolf SteelCet appareil doit être entretenu annuellemen

Page 49 - W415-0434 / E / 11.19.11

NAPOLÉON® garantit ses produits contre les défauts de fabrication à l’acheteur d’origine seulement. L’enregistrement de la garantie n’est pas nécessai

Page 50 - 15.0 NOTES

SYMPTÔME PROBLÈME SOLUTIONSLa veilleuse nes’allume pas.Aucune étincelle au brûleur de la veilleuse. - Véri ez si la veilleuse peut être allumée avec

Page 51 - 14.0 HISTORIQUE D’ENTRETIEN

SYMPTÔME PROBLÈME SOLUTIONSLe brûleur principal s’éteint; la veilleuse reste allumée.La  amme de la veilleuse n’est pas assez puissante ou n’envelopp

Page 52 - 13.0 GARANTIE

46W415-0434 / E / 11.19.1135373814**18135427231243426126651653641235292456741601536403969605117

Page 53 - THERMOPILE

45W415-0434 / E /11.19.11ACCESSOIRESNo RÉF. No PIÈCE DESCRIPTION49* W010-1777 ASSEMBLAGE DE L’ESPACEUR COUPE-FEU50* W500-0103 EXTENSION DE TERMINAISON

Page 54

44W415-0434 / E / 11.19.11 COMPOSANTSNo RÉF. No PIÈCE DESCRIPTION25* W290-0080 JOINT D’ÉTANCHÉITÉ DE LA PLAQUE DE RECOUVREMENT26 W062-0005 SOUFFLERIE2

Page 55

Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de rechange. Normalement, toutes les pièces peuvent ê

Page 56 - ACCESSOIRES

!AVERTISSEMENTRISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE.COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’A

Page 57 - ENSEMBLES D’ÉVENTS

6W415-0434 / G / 08.08.112.3 GENERAL INFORMATION4.1A The installation must conform with local codes or, in absence of local codes, the National Gas an

Page 58 - AVERTISSEMENT

41W415-0434 / E /11.19.1110.1 REMPLACEMENT DE LA LUMIÈRE DE VEILLEVotre appareil est équipé d’une lumière de veille précâblée qui peut être contrôlée

Page 59

ATTENTION : Lors de l’entretien des contrôles, assurez-vous d’identi er chacun des  ls avant de les débrancher. Une réinstallation incorrecte des 

Page 60 - LENTILLE

77.1Certaines con gurations d’évacuations verticales peuvent avoir une  amme très active. Si cette apparence n’est pas désirée, la sortie du conduit

Page 61

VEILLEUSETHERMOCOUPLETHERMOPILEAjustez la vis de la veilleuse pour obtenir une  amme de taille normale. Tournez vers la droite pour réduire l’apport

Page 62

Assurez-vous que l'arrivée de gaz au brûleur est continue avant de réinstaller la porte. Lorsqu'il est allumé pour la première fois, l’appar

Page 63

!AVERTISSEMENTN’UTILISEZ PAS CE FOYER SI UNE PARTIE QUELCONQUE A ÉTÉ SUBMERGÉE. CONTACTEZ IMMÉDIATEMENT UN TECHNICIEN DE SERVICE QUALIFIÉ POUR INSPECT

Page 64

32.1Éparpillez les braises à l’avant et sur les côtés du support à bûches de façon à créer un effet réaliste. N’utilisez pas la fi ne poussière qui res

Page 65

34W415-0434 / E / 11.19.1115432A. Centrez les deux bandes de charbon de bois tel qu’illustré, le long du bord intérieur avant de la chambre de combus

Page 66 - 6.10 MISE EN PLACE DU LOGO

!AVERTISSEMENTOMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CE

Page 67

!AVERTISSEMENTRISQUE D’INCENDIE!N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. LA FAÇADE DE L’APPAREIL DOIT ÊTRE FAITE DE MATÉRIAUX INCOMB

Page 68

7W415-0434 / G / 08.08.112.4 RATING PLATE INFORMATION VENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLA

Page 69

!AVERTISSEMENTRISQUE D’INCENDIE. CONSERVEZ TOUS LES DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLESSPÉCIFIÉS. NE PAS RESPECTER CES INSTRUCTIONS PEUT CAUSER UN

Page 70

30W415-0434 / E / 11.19.11!AVERTISSEMENTN’UTILISEZ QUE DES MATÉRIAUX INCOMBUSTIBLES TELS QU’UN PANNEAU DE CIMENT, DES CARREAUX DE CÉRAMIQUE, DU MARBRE

Page 71

29W415-0434 / E /11.19.11401/8"373/4"563/4"HABILLAGEINTÉRIEURHABILLAGEEXTÉRIEUR4"6"4"2”2”0”373/4"181/4"181/4&q

Page 72 - EXTÉRIEUR

!AVERTISSEMENTRISQUE D’INCENDIE!AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CON-TACT AVEC L’EXTÉRIEUR DU CAISSON, IL

Page 73

Pour faciliter l’accès, un interrupteur mural ou un thermostat millivolt optionnel peut être installé à un endroitpratique. Passez un  l millivolt à

Page 74

30.1AL’installation et l’entretien doivent être effectués par un installateur quali é. A. Mettez l’appareil en place et  xez-le.B. Si l’appareil est

Page 75

A. Mettez l’appareil en place.B. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel. Dans ce cas, l’évent

Page 76 - D’ÉVACUATION

A. Raccordez la gaine  exible de 8” de diamètre à l’appareil. Fixez-la à l’aide de trois vis et de trois rondelles. Scellez le joint et les têtes de

Page 77 - TEMPÉRATURE

2”COLLET DE SOLINSOLINCALFEUTRAGESCELLANTBASE DE PRISE D’AIRGAINE FLEXIBLEGAINE FLEXIBLEGAINEINTÉRIEURESCELLANT À HAUTETEMPÉRATURECONNECTEUR DE TERMIN

Page 78

A. Étirez la gaine  exible intérieure à la longueur requise en tenant compte de la longueur additionnelle nécessaire pour la surface du mur  ni. A

Page 79 - EXTÉRIEURE

8W415-0434 / G / 08.08.113.0 VENTING7.1ATHIS APPLIANCE USES A 4” EXHAUST / 7” AIR INTAKE VENT PIPE SYSTEM.Refer to the section applicable to your inst

Page 80 - ESPACEURS

A n d’assurer une opération sécuritaire et adéquate de l’appareil, vous devez observer les instructions d’évacuation à la lettre.Tous les joints des

Page 81 - 4.1.2 INSTALLATION VERTICALE

Cette con guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont d

Page 82

Cette con guration s’applique lorsque le conduit d’évent traverse un mur extérieur. Une fois que vous aurez déterminé la hauteur exacte pour l’emplac

Page 83

!AVERTISSEMENTAFIN D’ASSURER UN FONCTIONNEMENT SÉCURITAIRE ET ADÉQUAT DE L’APPAREIL, VOUS DEVEZ OBSERVER LES INSTRUCTIONS D’ÉVACUATION À LA LETTRE.TOU

Page 84

(HT) > (VT)Configuration d'évacuation simple.Consultez le graphique pour déterminer la course verticale nécessaire VT par rapport à la course

Page 85 - 3.9 TERMINAISON VERTICALE

(HT) < (VT)Configuration d'évacuation simple.Consultez le graphique pour déterminer la course verticale nécessaire VT par rapport à la course

Page 86

15W415-0434 / E /11.19.11(HT) > (VT)Configuration d'évacuation simple (un coude de 90° seulement).Consultez le graphique pour déterminer la co

Page 87

(HT) < (VT)Configuration d'évacuation simple (un coude de 90° seulement).Consultez le graphique pour déterminer la course verticale nécessaire

Page 88 - 3.6 DÉFINITIONS

13.1Terminaison horizontaleTerminaison verticaleLa course verticale est plus grande ou égale à la course horizontale.La course verticale est plus peti

Page 89

INSTALLATIONCANADA É.-U.A 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon.B 12” 9” Dégagement des fenêtres

Page 90 - 3.3.1 ENSEMBLE PÉRISCOPIQUE

9W415-0434 / G / 08.08.113.1 VENTING LENGTHS AND COMPONENTSUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or M

Page 91

Utilisez l’ensemble périscopique a n de positionner la terminaison au-dessusdu niveau du sol. L’ensemble périscopique doit être installé de façon à c

Page 92 - ÉVACUATION DIRECTE

45.610W415-0434 / E / 11.19.11LE PREMIER DEUX PIEDS DE CONDUIT EXTÉRIEUR DE 7” DE DIAMÈTRE À PAR-TIR DE L’APPA-REIL DOIT ÊTRE ENVELOPPÉ DANS UN MANCHO

Page 93

Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimum

Page 94 - ÉCHANTILLON

CET APPAREIL UTILISE UN SYSTÈME DE CONDUITS DE 4” POUR L’ÉVACUATION ET DE 7” POUR LA PRISE D’AIR.Veuillez consulter la section qui correspond à votre

Page 95 - 2.3 INFORMATIONS GÉNÉRALES

HVENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALL

Page 96

4.1A L’installation doit se conformer aux codes locaux. En l’absence de codes locaux, l’installation doit être conforme au Code d’installation du gaz

Page 97

CET APPAREIL AU GAZ DEVRAIT ÊTRE INSTALLÉ ET ENTRETENU PAR UN INSTALLATEUR QUALIFIÉ en se conformant aux codes locaux. Les pratiques d’installation pe

Page 98 - 1.0 SURVOL DE L’INSTALLATION

3.1C!AVERTISSEMENT• CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT.• TOUTE MODIFICATION APPORTÉE À

Page 99 - TABLE DES MATIÈRES

3W415-0434 / E /11.19.11Porte, voir la section « INSTALLATION DE LA PORTE ». Persiennes, voir la section« INSTALLATION DES PERSIENNES ».Évacuation, vo

Page 100 - AVERTISSEMENT

2W415-0434 / E / 11.19.11TABLE DES MATIÈRES1.0 SURVOL DE L’INSTALLATION 32.0 INTRODUCTION 42.1 DIMENSIONS 52.2 INSTRUCTIONS GÉNÉRALES 52.3 INFORM