Napoleon-fireplaces Vector 50 - LHD50 User Manual

Browse online or download User Manual for Kiln Napoleon-fireplaces Vector 50 - LHD50. Napoleon Fireplaces Vector 50 - LHD50 Manuel d'utilisation

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
EN
FR
PG
69
W415-0745 / F / 08.26.13
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • [email protected]
1.36C
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
CERTIFIED
Decorative Product: Not for use as a heating appliance.
LHD50N
LHD50N2
NATURAL GAS
LHD50P
LHD50P2
PROPANE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.50 CSA 2.22 FOR VENTED GAS APPLIANCES.
LHD50N ILLUSTRATED
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.50 CSA 2.22 FOR VENTED GAS FIREPLACES.
Page view 0
1 2 3 4 5 6 ... 135 136

Summary of Contents

Page 1 - OPERATING INSTRUCTIONS

ENFRPG69W415-0745 / F / 08.26.13$10.00INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE

Page 2 - TABLE OF CONTENTS

10W415-0745 / F / 08.26.13ENENUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. M

Page 3 - 1.0 INSTALLATION OVERVIEW

FRW415-0745 / F / 09.13.13100 * À l’intérieur de l’enceinte, un dégagement de 6’’ (152mm) est requis entre le haut du conduit d’évacuation et les mat

Page 4 - 2.0 INTRODUCTION

FRW415-0745 / F / 09.13.13 101NON-COMBUSTIBLEOSSATUREEN ACIERHAUT DEL’OUVERTUREDE L’APPAREIL32"813mmCOMBUSTIBLE9"229mm9"229mm68 1/4&quo

Page 5 - 2.1 DIMENSIONS

FRW415-0745 / F / 09.13.13102 5.4 INSTALLATION DU MATÉRIAUX INCOMBUSTIBLESi vous utilisez le matériau incombustible, toute la surface doit être couv

Page 6 - 2.2 GENERAL INSTRUCTIONS

FRW415-0745 / F / 09.13.13 103AVERTISSEMENT : Les matériaux de fi nition non combustibles ajustés sur le cadre, autour de la porte d’opération, ne doiv

Page 7 - 2.3 GENERAL INFORMATION

FRW415-0745 / F / 09.13.13104 Le dégagement d’une tablette combustible peut varier selon la profondeur de la tablette. Utilisez le graphique pour vou

Page 8

FRW415-0745 / F / 09.13.13 1056.0 FINITIONS6.1 INSTALLATION/ENLÈVEMENT DE LA PORTE!AVERTISSEMENTRISQUE D’INCENDIE!N’OBSTRUEZ JAMAIS L’OUVERTURE SUR L

Page 9 - 2.5 SHIPPING HANDLES

FRW415-0745 / F / 09.13.13106 CÔTÉ D’ACCÈSPANNEAU D’ACCÈS DE PRÉINSTALLATION!AVERTISSEMENTN’INSERE PAS LES DOIGTS DANS L’ECART ENTRE LA PORTE ET L’OS

Page 10 - 3.0 VENTING

FRW415-0745 / F / 09.13.13 1076.2 BRAISES VITRIFIÉESNOTE : Assurez-vous que les braises vitrifi ées n’encombrent pas l’emplacement de la veilleuse et q

Page 11 - W415-0745 / F / 08.26.13

FRW415-0745 / F / 09.13.13108 6.3 EMPLACEMENT DES ROCHES OPTIONNELLESLOGO6.4 MISE EN PLACE DU LOGOÉparpillez les roches réfractaires sur le plateau

Page 12 - 3.3.1 PERISCOPE TERMINATION

FRW415-0745 / F / 09.13.13 109Si vous devez accéder à la zone des commandes AVANT L’INSTALLATION, retirez le panneau d’accès de pré-installation. Vous

Page 13

11W415-0745 / F / 08.26.13EN40 FT (12M)MAXIMUM3 FT (1M)MINIMUM16” (406MM)MINIMUM36” (914MM)15” (381MM) MINIMUM24” (610MM) MAXIMUM51” (1295MM) MINIMUM

Page 14

FRW415-0745 / F / 09.13.13110 7.3 INSTALLATION DU RÉCEPTEURLe récepteur doit être situé à une dis-tance maximale de 8 pieds de ce côté de l’appareil

Page 15 - 3.8 HORIZONTAL TERMINATION

FRW415-0745 / F / 09.13.13 1117.4 SCHÉMA!AVERTISSEMENTNE BRANCHEZ PAS LE 110 V À LA SOUPAPE OU À L’INTERRUPTEUR MURAL DE L’APPAREIL.SOUPAPE À MODULATI

Page 16 - ) > (V

FRW415-0745 / F / 09.13.13112 THERMOSTATOFF/ON/SMARTROOM TEMPERATURELOW BATTERYALARMCHILD SAFETY LOCK OUTTRANSMISSIONAUX. OUTPUTFANFLAMETEMPERATURE S

Page 17 - 3.9 VERTICAL TERMINATION

FRW415-0745 / F / 09.13.13 113La télécommande peut fonctionner comme un thermostat de pièce. Le thermostat peut être réglé à une température désirée p

Page 18

FRW415-0745 / F / 09.13.13114 La télécommande comporte six (6) niveaux de fl ammes. Avec le système en marche et le niveau de la fl amme au maximum, ap

Page 19 - 4.0 INSTALLATION

FRW415-0745 / F / 09.13.13 115Le module de contrôle offre une prise 120 V AUX télécommandée pour la lumière de veille et une prise 120 V à alimentatio

Page 20 - 4.1.2 VERTICAL INSTALLATION

FRW415-0745 / F / 09.13.13116 CÔTÉ DROIT DU CADRE DE PORTE(CÔTÉ FONCTION-NEMENT)INTERRUPTEUR ANTICONDENSATIONCet appareil possède l’option de passer

Page 21

FRW415-0745 / F / 09.13.13 1179.0 INSTRUCTIONS DE FONCTIONNEMENTPOUR VOTRE SÉCURITÉ, LISEZ CE QUI SUIT AVANT D’ALLUMER :A. Cet appareil est équipé d

Page 22

FRW415-0745 / F / 09.13.13118 10.0 RÉGLAGESAjustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour rédu

Page 23 - ROOF SUPPORT

FRW415-0745 / F / 09.13.13 1193/8” - 1/2”(9,5mm - 12,7mm)LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDEDE FLAMME DE 3/8” (9,5mmÀ 1/2” (12,

Page 24 - 4.3 MOBILE HOME INSTALLATION

12W415-0745 / F / 08.26.13ENENUse the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grad

Page 25 - 20” (508mm)

FRW415-0745 / F / 09.13.13120 11.0 ENTRETIENATTENTION : Lors de l’entretien des contrôles, assurez-vous d’identifi er chacun des fi ls avant de les déb

Page 26 - 5.0 FRAMING

FRW415-0745 / F / 09.13.13 12111.2 ACCÈS AUX CONTRÔLESLorsque l’ossature et la fi nition sont terminées, l’accès aux contrôles ne peut se faire qu’en

Page 27 - 67 7/8"

FRW415-0745 / F / 09.13.13122 Retirez l’une des portes principales; voir la section « INSTALLATION / ENLÈVEMENT DE LA PORTE ». Retirez le plateau de

Page 28 - 5.1 TWO SIDED APPLIANCE

FRW415-0745 / F / 09.13.13 123A. Enlevez l’assemblage de la soupape et mettez de côté. Voir la section « ASSEMBLAGE DE LA SOUPAPE ». Débranchez les fi

Page 29

FRW415-0745 / F / 09.13.13124 11.8 REMPLACEMENT DE L’AMPOULECet appareil est équipé de nos lumières « CrystalitesMD ». Si vous devez remplacer l’amp

Page 30 - 5.2 ONE SIDE APPLIANCE

FRW415-0745 / F / 09.13.13 12511.10 ENLÈVEMENT DU PANNEAU RÉFLECTEUR DE PORCELAINE EN FORME DE PRISME A. Enlevez le plateau de braises vitrifi ée

Page 31 - STAND OFF

5.1NE PAS NETTOYER LA VITRE LORSQU’ELLE EST CHAUDE! N’EMPLOYEZ PAS DE DÉTERGENTS ABRASIFS POUR NETTOYER LA VITRE. Polissez légèrement à l’aide d’un li

Page 32

FRW415-0745 / F / 09.13.13 127NOTE : Usez de prudence lorsque vous enlevez et jetez des débris de verre ou des composants endommagés. Assurez-vousd’as

Page 33

FRW415-0745 / F / 09.13.13128 ACCESSOIRESNº RÉF. N° DE PIÈCE DESCRIPTION37* W573-0007 SCELLANT À HAUTE TEMPÉRATURE38 GD501 PROTECTEUR DE CHALEUR39* W

Page 34

FRW415-0745 / F / 09.13.13 12936353433432191214284353101921202223413852514626

Page 35

13W415-0745 / F / 08.26.13ENINSTALLATIONSCANADA U.S.A.A 12” (305mm) 12” (305mm) Clearance above grade, veranda porch, deck or balcony.B 12” (305mm)Δ9”

Page 36 - SIDE VIEW

FRW415-0745 / F / 09.13.13130 13.0 GUIDE DE DÉPANNAGE42.1CSYMPTÔME PROBLÈME SOLUTIONSLa télécommande contrôle les lumières Crystalite / lumière de v

Page 37

FRW415-0745 / F / 09.13.13 131SYMPTÔME PROBLÈME SOLUTIONSOn détecte l’odeur des gaz de combustion dans la pièce; maux de tête.L’appareil refoule les g

Page 38 - 6.0 FINISHING

FRW415-0745 / F / 09.13.13132 42.1_3BSYMPTÔME PROBLÈME SOLUTIONSÉtincelle à la veilleuse mais celle-ci ne s’allume pas.Alimentation en gaz. - Vérifi

Page 39 - Door Latch

FRW415-0745 / F / 09.13.13 133NAPOLÉON® garantit ses produits contre les défauts de fabrication à l’acheteur d’origine seulement. L’enregistrement de

Page 40 - 6.2 GLASS MEDIA INSTALLATION

FRW415-0745 / F / 09.13.13134 Date43.1Problèmes particuliersTravail effectuéNom du technicienDétaillantHistorique d’entretien Wolf SteelCet appareil

Page 41 - 6.5 UNIQUE INSTALLATIONS

FRW415-0745 / F / 09.13.13 13516.0 NOTES44.1

Page 42 - 7.0 ELECTRICAL CONNECTION

Autres produits Napoléon®Foyers encastrés • Grils au charbon de bois • Foyers au gaz • Cascades d’eau Poêles à bois • Produits HVAC • Foyers électriqu

Page 43 - ON REMOTE OFF

14W415-0745 / F / 08.26.13ENEN13.3ATOP EXITHorizontal TerminationVertical TerminationVertical rise is equal to or greater than the horizontal runVerti

Page 44 - 7.4 SCHEMATIC

15W415-0745 / F / 08.26.13EN16.1BSimple venting confi guration (only one 90° elbow)(HT) < (VT)For vent confi gurations requiring more than one 90° el

Page 45 - 8.0 OPERATION

16W415-0745 / F / 08.26.13ENEN(HT) > (VT) Simple venting configuration (only one 90° elbow)See graph to determine the required vertical rise VT for

Page 46 - 8.7 FLAME HEIGHT

17W415-0745 / F / 08.26.13EN(HT) < (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horizon

Page 47 - 8.8 CHILD PROOF FUNCTION

18W415-0745 / F / 08.26.13ENEN(HT) > (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horiz

Page 48 - 8.14 TIMED BLOWER

19W415-0745 / F / 08.26.13ENFor optimum performance it is recommended that all horizontal runs have a minimum of 1/4” (6mm) rise per foot using fl exib

Page 49 - 9.0 OPERATING INSTRUCTIONS

2W415-0745 / F / 08.26.13ENENTABLE OF CONTENTSNOTE: Changes, other than editorial, are denoted by a vertical line in the margin.1.0 INSTALLATION OVERV

Page 50 - 10.0 ADJUSTMENT

20W415-0745 / F / 08.26.13ENENThis application occurs when venting through an exterior wall. Having determined the correct height for the air terminal

Page 51 - 10.4 FLAME CHARACTERISTICS

21W415-0745 / F / 08.26.13ENFor safe and proper operation of the appliance, follow the venting instructions exactly.All inner fl ex pipe and outer fl ex

Page 52 - MAINTENANCE

22W415-0745 / F / 08.26.13ENENA. Stretch the inner fl ex pipe to the required length needed for the fi nished wall surface. Apply a heavy bead of high

Page 53 - 11.2 CONTROL ACCESS

23W415-0745 / F / 08.26.13ENA. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting

Page 54 - 11.4 VALVE REMOVAL

24W415-0745 / F / 08.26.13ENENA. Install the inner fl ex pipe to the appliance. Secure with 3 screws and fl at washers. Seal the joint and screw holes

Page 55 - MEDIA TRAY

25W415-0745 / F / 08.26.13EN30.1Installation and servicing to be done by a qualifi ed installer. Do not use open fl ame.• Move the appliance into posit

Page 56

26W415-0745 / F / 08.26.13ENENMaintain these minimum clearances to combustibles from appliance and vent surfaces:Appliance framing:Use steel stud fram

Page 57 - 11.10 PORCELAIN WRAP

27W415-0745 / F / 08.26.13EN*HORIZONTAL VENT SECTIONS: A minimum clearance of 3” (76mm) to the top and 2” (51mm) to the sides and bottom of the vent p

Page 58 - 11.14 CARE OF PLATED PARTS

28W415-0745 / F / 08.26.13ENEN!WARNINGEDGES ARE SHARP, ALWAYS WEAR GLOVES WHEN WORKING WITH SHEET METAL.A. Lift the frame up and secure with the scre

Page 59 - 12.0 REPLACEMENTS

29W415-0745 / F / 08.26.13EN2"51mmMINMETAL STUDS2"51mmMIN2"51mmMIN2"51mmMINMETAL STUDS67 7/8"1724mm13 1/2"343mmMETAL STU

Page 60 - ROOF TERMINAL KITS

3W415-0745 / F / 08.26.13EN1.0 INSTALLATION OVERVIEWSee the section “VENTING - VENTING LENGTHS AND AIR TERMINAL LOCATIONS”See the section “FRAMING - M

Page 61

30W415-0745 / F / 08.26.13ENEN12METAL HEADERMETAL STUD!WARNINGEDGES ARE SHARP, ALWAYS WEAR GLOVES WHEN WORKING WITH SHEET METAL.A. Lift the frame up

Page 62 - 13.0 TROUBLESHOOTING

31W415-0745 / F / 08.26.13EN* When constructing the enclosure allow for fi nishing material thickness to maintain clearances.IMPORTANT: Before fi nishin

Page 63 - SYMPTOM PROBLEM TEST SOLUTION

32W415-0745 / F / 08.26.13ENEN* Within the appliance enclosure a 6” (152mm) clearance between the top of the vent pipe and combustible materials is re

Page 64

33W415-0745 / F / 08.26.13EN* Within the appliance enclosure a 6” (152mm) clearance between the top of the vent pipe and combustible materials is requ

Page 65 - 14.0 WARRANTY

34W415-0745 / F / 08.26.13ENENNON-COMBUSTIBLESTEEL STUD FRAMETOP OFAPPLIANCEOPENING32"813mmCOMBUSTIBLE9"229mm9"229mm68 1/4"1734mm5

Page 66 - 15.0 SERVICE HISTORY

35W415-0745 / F / 08.26.13EN!WARNING5.4 INSTALLING NON-COMBUSTIBLE BOARDIf using the supplied non-combustible board that entire surface must be cover

Page 67

36W415-0745 / F / 08.26.13ENENWARNING: Non-combustible fi nishing material tight to the frame around the operating door must not project more than 1” (

Page 68 - Products

37W415-0745 / F / 08.26.13ENCombustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed.0

Page 69

38W415-0745 / F / 08.26.13ENEN6.0 FINISHING6.1 DOOR REMOVAL / INSTALLATION!WARNINGGLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.THE DOOR LATCHES

Page 70 - TABLE DES MATIÈRES

39W415-0745 / F / 08.26.13ENACCESS SIDEPRE-FINISHINGACCESS PANEL!WARNINGDO NOT INSERT FINGERS IN THE GAP BETWEEN THE DOOR AND THE FRAMING EDGE, THERE

Page 71 - 1.0 SURVOL DE L’INSTALLATION

4W415-0745 / F / 08.26.13ENEN3.2B!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES OR ALTERATIONS

Page 72

40W415-0745 / F / 08.26.13ENENWARNING: DO NOT PLACE MEDIA ON OR AROUND THE PILOT, THIS WILL INTERFERE WITH PILOT OPERATION. USE ONLY MEDIA APPROVED FO

Page 73

41W415-0745 / F / 08.26.13EN6.3 OPTIONAL ROCK PLACEMENTLOGO6.4 LOGO PLACEMENTRandomly place the refractory rocks onto the media tray, around, but not

Page 74

42W415-0745 / F / 08.26.13ENENIf access to the control area is necessary BEFORE INSTALLATION, remove the pre-fi nishing access panel. The access panel

Page 75 - 2.3 INFORMATIONS GÉNÉRALES

43W415-0745 / F / 08.26.13ENReceiver must be located within 8 feet of this side of the appliance and must be accessible for programming the remote.Ins

Page 76

44W415-0745 / F / 08.26.13ENEN7.4 SCHEMATICWIRE HARNESS ASSEMBLYIPI BOARDPILOTGROUNDWIREEI PILOTSPARK ELECTRODEFLAME SENSORVALVEELECTRONIC MODULATIONA

Page 77

45W415-0745 / F / 08.26.13EN8.0 OPERATIONIF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERS

Page 78 - ÉVACUATION DIRECTE

46W415-0745 / F / 08.26.13ENENThe remote transmitter can operate as a room thermostat. The thermostat can be set to a desired temperature to control t

Page 79

47W415-0745 / F / 08.26.13ENThe auxiliary function controls the AUX power outlet on the Control Module which controls the Crystalites™. A. Use the Mo

Page 80 - 3.3.1 ENSEMBLE PÉRISCOPIQUE

48W415-0745 / F / 08.26.13ENENThe control module offers a remotely actuated 120V AUX outlet for the accent lights and a constantly powered 120V outlet

Page 81

49W415-0745 / F / 08.26.13EN9.0 OPERATING INSTRUCTIONSIF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY

Page 82

5W415-0745 / F / 08.26.13EN37 3/16"945mm36"914mm13 1/2"343mm16 1/4"413mmELECTRICALINLETELECTRICALINLETGASINLETACCESS SIDEGASINLET5

Page 83 - 3.8 TERMINAISON HORIZONTALE

50W415-0745 / F / 08.26.13ENEN10.0 ADJUSTMENT10.1 RESTRICTING VERTICAL VENTSAdjust the pilot screw to provide properly sized fl ame. Turn in a clockwi

Page 84

51W415-0745 / F / 08.26.13EN10.3 VENTURI ADJUSTMENTVENTURI ADJUSTMENT CHARTFUEL LHD50NG 1/8” (3mm)LP 1/4” (6mm)This appliance has an air shutter that

Page 85 - 3.9 TERMINAISON VERTICALE

52W415-0745 / F / 08.26.13ENENCAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous

Page 86

53W415-0745 / F / 08.26.13EN11.2 CONTROL ACCESSOnce the appliance has been framed and fi nished, control access can only be achieved by removing the va

Page 87

54W415-0745 / F / 08.26.13ENENRemove one of the main doors, see “DOOR REMOVAL / INSTALLATION” section. Remove the media tray, see “BURNER REMOVAL” sec

Page 88

55W415-0745 / F / 08.26.13ENA. Remove the valve train assembly and set aside, see “VALVE TRAIN ASSEMBLY” section. Disconnect the wires to the control

Page 89

56W415-0745 / F / 08.26.13ENEN11.8 LAMP REPLACEMENTThis appliance comes equipped with our “Crystalites™”. If in the event the lamp needs to be replace

Page 90

57W415-0745 / F / 08.26.13EN11.10 PORCELAIN WRAP A. Remove Media Tray, see “BURNER REMOVAL” section. NOTE: For One Side appliance, the porcelain wr

Page 91

58W415-0745 / F / 08.26.13ENEN11.12 GLASS / DOOR REPLACEMENT 11.13 CARE OF GLASS 5.1DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLE

Page 92

59W415-0745 / F / 08.26.13ENNOTE: Care must be taken when removing and disposing of any broken glass or damaged components. Be sure to vacuum up any b

Page 93

6W415-0745 / F / 08.26.13ENEN4.1BTHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installatio

Page 94

60W415-0745 / F / 08.26.13ENENACCESSORIESREF NO. PART NO. DESCRIPTION37* W573-0007 HI-TEMP SEALANT38 GD-501 HEAT GUARD39* W010-0370 WALL SUPPORT ASSEM

Page 95

61W415-0745 / F / 08.26.13EN36353433432191214284353101921202223413852514626

Page 96

62W415-0745 / F / 08.26.13ENEN13.0 TROUBLESHOOTINGSYMPTOM PROBLEM TEST SOLUTIONRemote controls Crystalite / Night light but no spark or fl ame.Remote i

Page 97

63W415-0745 / F / 08.26.13ENExhaust fumes smelled in room, headaches.Appliance is spilling. - Check door seal. - Check for exhaust damage. - Check th

Page 98

64W415-0745 / F / 08.26.13ENEN42.1_3BSYMPTOM PROBLEM TEST SOLUTIONPilot sparks but will not light.Gas supply. - Verify that the incoming gas line bal

Page 99

65W415-0745 / F / 08.26.13ENNAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is

Page 100 - W415-0745 / F / 09.13.13

W415-0745 / F / 07.04.1366 EN43.115.0 SERVICE HISTORY

Page 101

W415-0745 / F / 07.04.13 67EN44.116.0 NOTES

Page 102 - AVERTISSEMENT

Other Napoleon® ProductsFireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces •

Page 103

INSTALLATEUR : LAISSEZ CE MANUEL AVEC L’APPAREIL. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.NE LAISSEZ PAS LES ENFANTS OU AUTRES

Page 104 - DE L’APPAREIL

7W415-0745 / F / 08.26.13ENWhen the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations from th

Page 105

FRW415-0745 / F / 09.13.1370 NOTE : Les changements autres que de nature éditoriale sont dénotés par une ligne verticale dans la marge.TABLE DES MATI

Page 106

1.0 SURVOL DE L’INSTALLATIONVoir la section « ÉVACUATION - LONGUEURS DES CONDUITS D’ÉVACUATION ET EMPLACEMENTS DE LA TERMINAISON »Voir la section « OS

Page 107

3.2B!AVERTISSEMENT• CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT.• TOUTE MODIFICATION APPORTÉE À

Page 108 - 6.4 MISE EN PLACE DU LOGO

37 3/16"945mm36"914mm13 1/2"343mm16 1/4"413mmENTRÉEÉLECTRIQUECÔTÉ D’ACCÈS50 1/4"1276mm67 3/8"1711mm8"203mm5"12

Page 109

4.1BCET APPAREIL AU GAZ DEVRAIT ÊTRE INSTALLÉ ET ENTRETENU PAR UN INSTALLATEUR QUALIFIÉ en se conformant aux codes locaux. Les pratiques d’installatio

Page 110 - ON REMOTE OFF

Lorsque l’appareil est installé à des élévations dépassant 4 500 pieds (1372m), et en l’absence de recommandations spécifi ques de l’autorité compétent

Page 111

2.4 EMPLACEMENT DE LA PLAQUE D’HOMOLOGATION/ DES INSTRUCTIONS D’ALLUMAGECERTIFIED UNDER / HOMOLOGUE SELON LES NORMES:VENTED GAS FIREPLACE. APPROVED F

Page 112

2.5 POIGNÉES DE TRANSPORTIMPORTANTCet appareil y compris tous ses accessoires pèse 300 lb.A. Soulevez et fi xez l’ensemble d’ossature. Pour les instr

Page 113 - 8.6 THERMOSTAT SMART

FRW415-0745 / F / 09.13.1378 Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Ameri

Page 114 - 8.9 CRYSTALITES

36”15” (381MM) MINIMUM24” (610MM) MAXIMUM51” (1295MM)MINIMUM PLUS L’ÉLÉVATION* * Voir la section « ÉVACUATION ».40 PIEDS (12M)MAXIMUM3 PIEDS (1M)MINIM

Page 115 - 8.12 MODULE DE CONTRÔLE

8W415-0745 / F / 08.26.13ENEN2.4 RATING PLATE / LIGHTING INSTRUCTION LOCATIONCERTIFIED UNDER / HOMOLOGUE SELON LES NORMES:VENTED GAS FIREPLACE. APPRO

Page 116 - 8.14 MINUTERIE DE SOUFFLERIE

Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à

Page 117

FRW415-0745 / F / 09.13.13 813.4 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON12.1DINSTALLATIONCANADA É.-U.A12” (304,8mm)12” (304,8mm)Dégage

Page 118 - 10.0 RÉGLAGES

FRW415-0745 / F / 09.13.1382 13.1ATerminaison horizontaleTerminaison verticaleLa course verticale est plus grande ou égale à la course horizontale.La

Page 119 - 10.3 RÉGLAGE DU VENTURI

FRW415-0745 / F / 09.13.13 83(HT) < (VT) Configuration d'évacuation simple (un coude de 90° seulement).Consultez le graphique pour déterminer

Page 120

FRW415-0745 / F / 09.13.1384 (HT) > (VT) Configuration d'évacuation simple (un coude de 90° seulement).Consultez le graphique pour déterminer

Page 121 - 11.2 ACCÈS AUX CONTRÔLES

FRW415-0745 / F / 09.13.13 85(HT) < (VT) Configuration d'évacuation simple.Consultez le graphique pour déterminer la course verticale nécessai

Page 122 - PRÉINSTALLATION

FRW415-0745 / F / 09.13.1386 (HT) > (VT) Configuration d'évacuation simple.Consultez le graphique pour déterminer la course verticale nécessa

Page 123 - 11.5 ENLÈVEMENT DU BRÛLEUR

FRW415-0745 / F / 09.13.13 87Pour une performance optimale de l’appareil, toutes les courses horizontales devraient avoir une élévation minimale de 1/

Page 124 - CRYSTALITES

FRW415-0745 / F / 09.13.1388 4.1.1 INSTALLATION HORIZONTALECette confi guration s’applique lorsque le conduit d’évent traverse un mur extérieur. Une f

Page 125 - DE PRISME

FRW415-0745 / F / 09.13.13 89Afi n d’assurer une opération sécuritaire et adéquate de l’appareil, vous devez observer les instructions d’évacuation à l

Page 126

9W415-0745 / F / 08.26.13ENIMPORTANTThis appliance fully dressed weighs 300 lbs. A. Lift up and secure the framing kit, see “STEEL STUD FRAMING KIT”

Page 127

FRW415-0745 / F / 09.13.1390 A. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel. Dans ce cas, l’évent d

Page 128 - ACCESSOIRES

FRW415-0745 / F / 09.13.13 914.2.3 RACCORDEMENT DES ÉVENTS À L’APPAREILA. Raccordez la gaine fl exible de 8” (203,2mm) de diamètre à l’appareil. Fixez

Page 129

FRW415-0745 / F / 09.13.1392 30.1AL’installation et l’entretien doivent être effectués par un installateur qualifi é. A. Mettez l’appareil en place e

Page 130

FRW415-0745 / F / 09.13.13 935.0 OSSATURE!AVERTISSEMENTRISQUE D’INCENDIE!AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN

Page 131 - SYMPTÔME PROBLÈME SOLUTIONS

FRW415-0745 / F / 09.13.1394 PPPP>PP@)52179,(:5,*+76,'(9,(:7239,(:LHD50

Page 132

FRW415-0745 / F / 09.13.13 955.1 APPAREIL BINAIRE!AVERTISSEMENTLES BORDS SONT COUPANTS. PORTEZ TOUJOURS DES GANTS LORSQUE VOUS TRAVAILLEZAVEC DES FEUI

Page 133 - CONDITIONS ET LIMITATIONS

FRW415-0745 / F / 09.13.1396 IMPORTANT : Avant d’effectuer la fi nition, vérifi ez le fonctionnement de l’appareil à l’aide de la télé- commande en te

Page 134 - 15.0 HISTORIQUE D’ENTRETIEN

FRW415-0745 / F / 09.13.13 975.2 APPAREIL À FACE UNIQUE!AVERTISSEMENTLES BORDS SONT COUPANTS. PORTEZ TOUJOURS DES GANTS LORSQUE VOUS TRAVAILLEZAVEC D

Page 135 - 16.0 NOTES

FRW415-0745 / F / 09.13.1398 * Lorsque vous construisez l’enceinte, prévoyez l’épaisseur des matériaux de fi nition pour maintenir les dé-gagements.IM

Page 136 - Autres produits Napoléon

FRW415-0745 / F / 09.13.13 995.3 DÉGAGEMENT MINIMAL AUX ENCEINTES COMBUSTIBLESIMPORTANT : Le LHD50 requiert une hauteur d’enceinte minimale de 60” (1

Comments to this Manuals

No comments