* Within the appliance enclosure a 6” (152mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the
enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 1”
(25mm) for vertical.
** See venting section.
2"
51mm
6"
152mm
6"
152mm *
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
3"
76mm
51"
1295mm
MINIMUM
PLUS RISE**
NON-COMBUSTIBLE
COMBUSTIBLE
TOP OF ENCLOSURE
(COMBUSTIBLE)
STEEL STUD
FRAME
32"
813mm
MINIMUM
TOP OF
APPLIANCE
OPENING
28"
711mm
MINIMUM
60"
1524mm
MINIMUM
ENCLOSURE
HEIGHT