Napoleon-fireplaces Vector 50 - LHD50 User Manual Page 54

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 53
54
W415-0745 / F / 08.26.13
EN
EN
Remove one of the main doors, see “DOOR REMOVAL
/ INSTALLATION” section. Remove the media tray, see
“BURNER REMOVAL” section. Remove the fourteen
screws from the valve train assembly. See “VALVE
REMOVAL” section.
11.3 VALVE TRAIN ASSEMBLY
SCREWS
A. Carefully lift the valve train assembly and turn
off the manual shut-off valve, see “VALVE
TRAIN ASSEMBLY” and “GAS INSTALLATION”
section.
NOTE: A new gasket may be required,
when re-installing the valve train assembly,
contact your local Authorized dealer /
distributor.
Disconnect the ex connector from the valve.
Remove the valve wire connections, labeling
each one to aid with re-connection.
B. Remove the four screws from the valve bracket
and remove the valve.
C. Replace all components before returning the
appliance to service.
D. Check for gas leaks by brushing on a soap and
water solution.
11.4 VALVE REMOVAL
VALVE
VALVE
BRACKET
GASKET