INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • [email protected]
1.28D
$10.00
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
Decorative Product: Not for use as a heating appliance.
LHD45N
NATURAL GAS
LHD45P
PROPANE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CSA 2.22 FOR VENTED GAS FIREPLACES.
SHOWN WITH OPTIONAL SURROUND
Page view 0
1 2 3 4 5 6 ... 119 120

Summary of Contents

Page 1 - OPERATING INSTRUCTIONS

ENW415-0834 / E / 06.13.13FRPG61INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE CHILDR

Page 2 - TABLE OF CONTENTS

W415-0834 / E / 06.13.1310 EN40 FEET(12.2M)MAXIMUM3 FEET(0.9M)MINIMUM16” (406.4mm)MINIMUM8” (203.2mm)MINIMUM18” (457.2mm) MAXIMUM (FLEX VENT)24” (609

Page 3 - 1.0 INSTALLATION OVERVIEW

7.2 INSTALLATION DE LA SOUFFLERIEW415-0834 / D / 06.27.13FR100 L’INSTALLATION DOIT ÊTRE FAITE PAR UN INSTALLATEUR QUALIFIÉ et doit être raccordée él

Page 4 - 2.0 INTRODUCTION

W415-0834 / D / 06.27.13FR 101!AVERTISSEMENTN’UTILISEZ PAS CE FOYER SI UNE PARTIE QUELCONQUE A ÉTÉ SUBMERGÉE. CONTACTEZ IMMÉDIATEMENT UN TECHNICIEN DE

Page 5 - 2.1 DIMENSIONS

W415-0834 / D / 06.27.13FR102 Vous devez effectuer un branchement par câble avec cet appareil.Une charpente permanente servant à encastrer l’appareil

Page 6 - 2.2 GENERAL INSTRUCTIONS

W415-0834 / D / 06.27.13FR 1038.3 SCHÉMA DE CÂBLAGE69.5A!AVERTISSEMENTNE RACCORDEZ PAS L’INTERRUPTEUR MURAL OU LA SOUPAPE DE GAZ À L’ALIMENTATION ÉLE

Page 7 - 2.3 GENERAL INFORMATION

W415-0834 / D / 06.27.13FR104 LIGHTING INSTRUCTIONS / INSTRUCTIONS D’ALLUMAGE1. STOP! READ ALL INFORMATION OF OPERATING AND LIGHTING INSTRUCT

Page 8 - 3.0 VENTING

W415-0834 / D / 06.27.13FR 105Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport d

Page 9

TABLEAU DE RÉGLAGE DU VENTURICOMBUSTIBLE LHD45GN 1/32” (0,8mm)PL 1/8” (3,2mm)10.3 CARACTÉRISTIQUES DE LA FLAMMEW415-0834 / D / 06.27.13FR106 L’ouver

Page 10 - W415-0834 / E / 06.13.13

11.0 ENTRETIEN11.1 ENTRETIEN ANNUELW415-0834 / D / 06.27.13FR 107ATTENTION : Lors de l’entretien des contrôles, assurez-vous d’identifi er chacun des fi

Page 11 - 3.3.2 CORNER TERMINATION

11.2 REMPLACEMENT DE LA VITRE/PORTEA. Placez le cadre de la porte, face vers le bas, en prenant soin de ne pas égratigner la peinture.B. Centrez la

Page 12 - 3.4 VENT TERMINAL CLEARANCES

11.4 SOINS DES PIÈCES PLAQUÉES11.5 ENLÈVEMENT DE LA SOUPAPE11.6 PLAQUE DE RESTRICTIONW415-0834 / D / 06.27.13FR 1096.1Si l’appareil est muni de piè

Page 13

W415-0834 / E / 06.13.13 11EN3.3 SPECIAL VENT INSTALLATIONS3.3.1 PERISCOPE TERMINATION3.3.2 CORNER TERMINATIONThe maximum vent length for a corner in

Page 14 - 3.8 HORIZONTAL TERMINATION

12.0 REPLACEMENTSW415-0834 / D / 06.27.13FR110 Contactez votre détaillant ou le fabricant pour les questions concernant les prix et la disponibilité

Page 15 - ) > (V

W415-0834 / D / 06.27.13FR 111ACCESSOIRESREF NO DE PIÈCE DESCRIPTION30LS45K CONTOUR À 4 CÔTÉS - NOIR31LDS45KCONTOUR DE LUXE À 4 CÔTÉS - NOIR31LDS45N C

Page 16 - 3.9 VERTICAL TERMINATION

W415-0834 / D / 06.27.13FR112 135415147161327981011

Page 17

W415-0834 / D / 06.27.13FR 1133328295337ATTENTION-CHAUDCAUTION - HOT32313043424154382122232725 262456OFF ON

Page 18 - * 40 FT (12.2m)

13.0 GUIDE DE DÉPANNAGEW415-0834 / D / 06.27.13FR114 SYMPTÔME PROBLÈME SOLUTIONSLa veilleuse ne s’allume pas.Il y a du bruit, mais aucune étincelle

Page 19

W415-0834 / D / 06.27.13FR 115SYMPTÔME PROBLÈME SOLUTIONSDu carbone se dépose sur la vitre, les bûches, les roches, les composants décoratifs ou les p

Page 20 - 4.0 INSTALLATION

W415-0834 / D / 06.27.13FR116 42.7_3BSYMPTÔME PROBLÈME SOLUTIONSUne pellicule blanche ou grisese forme.Le soufre du combustible se dépose sur la vitr

Page 21 - 4.1.2 VERTICAL INSTALLATION

14.0 GARANTIEW415-0834 / D / 06.27.13FR 117NAPOLÉON® garantit ses produits contre les défauts de fabrication à l’acheteur d’origine seulement. L’enreg

Page 22

15.0 HISTORIQUE D’ENTRETIENW415-0834 / D / 06.27.13FR118 Date43.1Problèmes particuliersTravail effectuéNom du technicienDétaillantHistorique d’entret

Page 23

16.0 NOTESW415-0834 / D / 06.27.13FR 119

Page 24 - FIREPLACE BASE

W415-0834 / E / 06.13.1312 EN3.4 VENT TERMINAL CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” (305mm) 12” (305mm) Clearance above grade, veranda porch, d

Page 25 - 4.9 GAS INSTALLATION

Autres produits Napoléon®Foyers encastrés • Grils au charbon de bois • Foyers au gaz • Cascades d’eauPoêles à bois • Produits HVAC • Foyers électrique

Page 26 - 4.10 INSTALLING CEMENT BOARD

W415-0834 / E / 06.13.13 13EN13.1ATOP EXITHorizontal TerminationVertical TerminationVertical rise is equal to or greater than the horizontal runVertic

Page 27 - 5.0 FRAMING

W415-0834 / E / 06.13.1314 EN16.1BSimple venting confi guration (only one 90° elbow)(HT) < (VT)For vent confi gurations requiring more than one 90°

Page 28 -

W415-0834 / E / 06.13.13 15EN(HT) > (VT) Simple venting configuration (only one 90° elbow)See graph to determine the required vertical rise VT for

Page 29 - OUTSIDE

W415-0834 / E / 06.13.1316 EN(HT) < (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horiz

Page 30 - * See “VENTING” section

W415-0834 / E / 06.13.13 17EN(HT) > (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horizo

Page 31

W415-0834 / E / 06.13.1318 EN3.10 VERTICAL THROUGH EXISTING CHIMNEY7.6AThis appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum

Page 32 - 5.2 ALCOVE ENCLOSURE

W415-0834 / E / 06.13.13 19ENFor shipping purposes, the heat shield has been attached on top of the appliance. If venting with a 90 degree elbow direc

Page 33 - 5.4 MINIMUM OVERHANG

W415-0834 / E / 06.13.132 ENNOTE: Changes, other than editorial, are denoted by a vertical line in the margin.TABLE OF CONTENTS1.0 INSTALLATION OVER

Page 34 - 6.0 FINISHING

W415-0834 / E / 06.13.1320 ENFor optimum performance it is recommended that all horizontal runs have a minimum of 1/4” (6.4mm) rise per 1ft (0.3m). F

Page 35 - 6.4 TRIM INSTALLATION

W415-0834 / E / 06.13.13 21EN4.1.1 HORIZONTAL INSTALLATIONThis application occurs when venting through an exterior wall. Having determined the correct

Page 36 - 6.5 GLASS EMBERS

W415-0834 / E / 06.13.1322 EN4.2 USING RIGID VENT COMPONENTSThe vent system must be supported approximately every 3 feet (0.9m) for both vertical an

Page 37 - 7.1.1 BURNER REMOVAL

W415-0834 / E / 06.13.13 23EN4.4 EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATIONA. Follow the instructions for "HORIZONTAL AIR TERMINAL I

Page 38 - 7.1.2 VALVE TRAIN ASSEMBLY

W415-0834 / E / 06.13.1324 ENThis appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactu

Page 39 - 7.2 INSTALLING THE BLOWER

W415-0834 / E / 06.13.13 25EN30.1Installation and servicing to be done by a qualifi ed installer. Do not use open fl ame.• Move the appliance into posi

Page 40 - 8.0 ELECTRICAL CONNECTION

W415-0834 / E / 06.13.1326 EN!WARNINGThe 14” (355.8mm) above the appliance opening must not be fi nished with any combustible materials.If only a pain

Page 41 - 8.1 HARD WIRING CONNECTION

W415-0834 / E / 06.13.13 27ENIt is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes

Page 42 - 8.3 WIRING DIAGRAM

W415-0834 / E / 06.13.1328 ENDO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR THE VENT IN THIS 14” (355.6mm) WID

Page 43 - 9.0 OPERATING INSTRUCTIONS

W415-0834 / E / 06.13.13 29ENINSIDECHASEOUTSIDE CHASE73 1/2"1867mm MINBACK WALL OF CHASE / ENCLOSURE (INCLUDING ANY FINISHING MA

Page 44 - 10.0 ADJUSTMENT

W415-0834 / E / 06.13.13 3EN1.0 INSTALLATION OVERVIEWMantel, see “MINIMUM MANTEL CLEARANCES” section.Enclosures, see the section “MINIMUM CLEARANCES T

Page 45 - 10.3 VENTURI ADJUSTMENT

W415-0834 / E / 06.13.1330 ENIMPORTANT: The LHD45 requires a minimum inside enclosure height of 56” (1422.4mm), measured from the bottom of the appli

Page 46 - MAINTENANCE

W415-0834 / E / 06.13.13 31ENCOMBUSTIBLENON-COMBUSTIBLETOP OF APPLIANCE OPENING30 11/16"780mm14"365mm42"1067mm46 1/4"1175mm2"

Page 47 - 11.2 ANNUAL MAINTENANCE

W415-0834 / E / 06.13.1332 EN5.2 ALCOVE ENCLOSUREAPPLIANCERECESS OR ALCOVE AREA NOTE: Recesses or alcoves above the appliance can be made as deep as

Page 48 - 11.6 CARE OF GLASS

W415-0834 / E / 06.13.13 33ENMANTEL DIMENSIONSRef Height DepthA 25 5/16” (642.9mm)B 6” (152.4mm) 2” (50.8mm)C 8” (203.2mm) 4” (101.6mm)D 10” (254mm) 6

Page 49 - ROOF TERMINAL KITS

W415-0834 / E / 06.13.1334 EN6.0 FINISHING6.1 DOOR REMOVAL / INSTALLATION!WARNINGGLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.THE DOOR LATCHES

Page 50 - TERMINAL KITS

W415-0834 / E / 06.13.13 35ENƎPPƎPPPlace trim as shown into the slots of the right and left brackets behind the access panel.LEFT BR

Page 51

W415-0834 / E / 06.13.1336 EN6.5 GLASS EMBERSNOTE: Care must be taken to ensure glass embers are kept .250” (6.35mm) clear of the pilot area on the m

Page 52

W415-0834 / E / 06.13.13 37EN7.0 OPTIONAL BLOWER INSTALLATION!WARNINGRISK OF FIRE AND ELECTRICAL SHOCK.TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SE

Page 53 - PILOT TUBE

W415-0834 / E / 06.13.1338 ENA. Remove the door, see “DOOR REMOVAL / INSTALLATION” section.B. Remove the media tray and burner, see “BURNER REMOVAL

Page 54 - SYMPTOM PROBLEM TEST SOLUTION

W415-0834 / E / 06.13.13 39EN7.2 INSTALLING THE BLOWERINSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounde

Page 55

W415-0834 / E / 06.13.134 EN3.2B!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES OR ALTERATIONS

Page 56 - 14.0 WARRANTY

W415-0834 / E / 06.13.1340 ENIf access to the control area is necessary BEFORE INSTALLATION, remove the pre-fi nishing access panel. The access panel

Page 57 - 15.0 SERVICE HISTORY

W415-0834 / E / 06.13.13 41ENIt is necessary to hard wire this appliance.Permanently framing the appliance with an enclosure, requires the appliance j

Page 58

W415-0834 / E / 06.13.1342 EN8.3 WIRING DIAGRAM69.5A!WARNINGDO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.ON / OFF SWITCHACS/IPI SWITCH(OPTIONAL)

Page 59

W415-0834 / E / 06.13.13 43EN9.0 OPERATING INSTRUCTIONSWhen lit for the fi rst time, the appliance will emit a slight odour for a few hours. This is a

Page 60 - Products

W415-0834 / E / 06.13.1344 EN9.3 ANTI CONDENSATION SWITCH (OPTIONAL)This appliance has the option to switch from an electronic intermittent pilot ig

Page 61

W415-0834 / E / 06.13.13 45EN10.2 FLAME CHARACTERISTICSIt’s important to periodically perform a visual check of the pilot and burner fl ames. Compare t

Page 62 - TABLE DES MATIÈRES

W415-0834 / E / 06.13.1346 EN11.0 MAINTENANCECAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause imprope

Page 63 - 1.0 SURVOL DE L’INSTALLATION

W415-0834 / E / 06.13.13 47EN11.2 ANNUAL MAINTENANCE37.1A!WARNINGTHE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL COMPLETELY OR W

Page 64

W415-0834 / E / 06.13.1348 ENA. Carefully lift the valve train assembly and turn off the manual shut-off valve, see “VALVE TRAIN ASSEMBLY” and “GAS

Page 65

W415-0834 / E / 06.13.13 49ENNOTE: Care must be taken when removing and disposing of any broken glass or damaged components. Be sure to vacuum up any

Page 66

W415-0834 / E / 06.13.13 5EN39 5/16"999mm40 13/16"1036mmGAS INLET10 1/8"257mm18 7/8"479mm19 7/8"505mm46 1/4"1175mm34 1/1

Page 67 - 2.3 INFORMATIONS GÉNÉRALES

W415-0834 / E / 06.13.1350 ENACCESSORIESREF PART NO. DESCRIPTION30LS45K 4 SIDED SURROUND - BLACK31LDS45KDELUXE 4 SIDED SURROUND - BLACK31LDS45N DELUX

Page 68 - ÉCHANTILLON

W415-0834 / E / 06.13.13 51EN135415147161327981011

Page 69 - ÉVACUATION DIRECTE

W415-0834 / E / 06.13.1352 EN3328295337ATTENTION-CHAUDCAUTION - HOT32313043424154382122232725 262456OFF ON

Page 70

W415-0834 / E / 06.13.13 53EN13.0 TROUBLESHOOTINGSYMPTOM PROBLEM TEST SOLUTIONPilot will not light.Makes noise with no spark at pilot burner.Wiring.

Page 71 - 3.3.2 TERMINAISON EN COIN

W415-0834 / E / 06.13.1354 ENSYMPTOM PROBLEM TEST SOLUTIONCarbon is being deposited on glass, logs, rocks, media or combustion chamber surfaces.Air s

Page 72

W415-0834 / E / 06.13.13 55EN42.7_3BSYMPTOM PROBLEM TEST SOLUTIONWhite / grey fi lm forms.Sulphur from fuel is being deposited on glass, logs or combus

Page 73

W415-0834 / E / 06.13.1356 ENNAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty

Page 74 - 3.8 TERMINAISON HORIZONTALE

W415-0834 / E / 06.13.13 57EN15.0 SERVICE HISTORY

Page 75

44.1W415-0834 / E / 06.13.1358 EN16.0 NOTES

Page 76 - 3.9 TERMINAISON VERTICALE

44.1W415-0834 / E / 06.13.13 59EN

Page 77

W415-0834 / E / 06.13.136 EN4.1BTHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installatio

Page 78

Other Napoleon® ProductsFireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces •

Page 79 - HAUTEUR

W415-0834 / D / 06.27.13FRINSTALLATEUR : LAISSEZ CE MANUEL AVEC L’APPAREIL. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.NE LAISSEZ

Page 80

TABLE DES MATIÈRESNOTE : Les changements autres que de nature éditoriale sont dénotés par une ligne verticale dans la marge.W415-0834 / D / 06.27.13FR

Page 81

1.0 SURVOL DE L’INSTALLATIONW415-0834 / D / 06.27.13FR 63Enceintes, voir la section « DÉGAGEMENTS MINIMAUX AUX ENCEINTES COMBUSTIBLES » pour les clois

Page 82 - 4.1.2 INSTALLATION VERTICALE

2.0 INTRODUCTIONW415-0834 / D / 06.27.13FR64 3.2B!AVERTISSEMENT• CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CA

Page 83 - ÉVACUATION

W415-0834 / D / 06.27.13FR 652.1 DIMENSIONS39 5/16"999mm40 13/16"1036mm10 1/8"257mmØ19 7/8"505mm18 7/8"479mm46 1/4"1175m

Page 84 - SCELLANT À

2.2 INSTRUCTIONS GÉNÉRALESW415-0834 / D / 06.27.13FR66 4.1BCET APPAREIL AU GAZ DEVRAIT ÊTRE INSTALLÉ ET ENTRETENU PAR UN INSTALLATEUR QUALIFIÉ en se

Page 85 - BASE DU FOYER

2.3 INFORMATIONS GÉNÉRALESPOUR VOTRE SATISFACTION, CET APPAREIL A ÉTÉ MIS À L’ESSAI POUR CONFIRMER SON FONCTIONNEMENT ET SA QUALITÉ!Lorsque l’appareil

Page 86

INSTALLATEUR : Vous êtes responsable de cocher les cases appropriées sur la plaque d’homologation selon le modèle, l’évacuation et le type de gaz de l

Page 87 - 14"

3.1 LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS POUR UNE ÉVACUATION DIRECTEW415-0834 / D / 06.27.13FR 69Utilisez uniquement des composants

Page 88

W415-0834 / E / 06.13.13 7EN2.3 GENERAL INFORMATIONAPPLIANCENG LPAltitude (FT) 0-4,500 0-4500Max. Input (BTU/HR) 24,000 24,000Max. Output Steady State

Page 89

37 13/16”(960,4mm)8” (203,2mm)MINIMUM48 3/4” (1163,6mm) MINIMUM PLUS L’ÉLÉVATION*40 PIEDS(12,2M)MAXIMUM3 PIEDS(0,9M)MINIMUM16” (406,4mm)MINIMUM37 13/1

Page 90

3.3.1 ENSEMBLE PÉRISCOPIQUE12” (304,8mm) MINIMUM AU NIVEAU DU SOL24” (609,6mm)MINIMUM40 13/16”(1036,6mm)3.3 INSTALLATIONS PARTICULIÈRES D’ÉVENTS3.3.2

Page 91

3.4 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISONW415-0834 / D / 06.27.13FR72 12.1DINSTALLATIONCANADA É.-U.A12” (304,8mm)12” (304,8mm)Dégag

Page 92

3.5 CHARTE D’APPLICATION DES ÉVACUATIONSW415-0834 / D / 06.27.13FR 7313.1ATerminaison horizontaleTerminaison verticaleLa course verticale est plus gr

Page 93 - 5.2 INSTALLATION EN ALCÔVE

3.8 TERMINAISON HORIZONTALEW415-0834 / D / 06.27.13FR74 (HT) > (VT) Configuration d'évacuation simple (un coude de 90° seulement).Consultez l

Page 94

(HT) > (VT) Configuration d'évacuation simple (un coude de 90° seulement).Consultez le graphique pour déterminer la course verticale nécessair

Page 95

3.9 TERMINAISON VERTICALEW415-0834 / D / 06.27.13FR76 (HT) < (VT) Configuration d'évacuation simple.Consultez le graphique pour déterminer la

Page 96 - SUPPORT GAUCHE

W415-0834 / D / 06.27.13FR 77(HT) > (VT) Configuration d'évacuation simple.Consultez le graphique pour déterminer la course verticale nécessai

Page 97

W415-0834 / D / 06.27.13FR78 3.10 TERMINAISON VERTICALE À TRAVERS UNE CHEMINÉE EXISTANTE7.6ACet appareil est conçu pour être raccordé à un système d

Page 98

W415-0834 / D / 06.27.13FR 793.11 INSTALLATION DU PROTECTEUR DE CONDUIT D’ÉVACUATIONLe protecteur de conduit d’évacuation a été fi xé au-dessus de l’a

Page 99

W415-0834 / E / 06.13.138 ENINSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting

Page 100 - W415-0834 / D / 06.27.13

4.1 PROTECTION DU MUR ET DU PLAFOND4.0 INSTALLATIONPour une performance optimale de l’appareil, toutes les courses horizontales devraient avoir une é

Page 101 - AVERTISSEMENT

4.1.1 INSTALLATION HORIZONTALEW415-0834 / D / 06.27.13FR 81Cette confi guration s’applique lorsque le conduit d’évent traverse un mur extérieur. Une fo

Page 102 - 8.1 BRANCHEMENT PAR CÂBLE

W415-0834 / D / 06.27.13FR82 Le système d’évacuation doit être soutenu à peu près tous les 3 pieds (0.9m) de courses verticales et horizontales. Util

Page 103

4.3 INSTALLATION DE LA TERMINAISON HORIZONTALE4.4 INSTALLATION ÉTENDUE DE LA TERMINAISON HORIZONTALEW415-0834 / D / 06.27.13FR 83VIS #10x2"COND

Page 104 - 9.2 INSTRUCTIONS D’ALLUMAGE

4.5 INSTALLATION DE LA TERMINAISON VERTICALEW415-0834 / D / 06.27.13FR84 A. Mettez l’appareil en place.B. Fixez le support de toit au toit à l’aid

Page 105 - 10.0 RÉGLAGES

4.6 UTILISATION DE COMPOSANTS FLEXIBLES D’ÉVACUATION4.8 INSTALLATION TÉLÉCOMMANDE35.25PLACER LE TÉLÉCOMMANDE SUR CETTE ÉTIQUETTEBASE DU FOYERBOÎTE DE

Page 106 - 10.2 RÉGLAGE DU VENTURI

4.9 BRANCHEMENT DU GAZW415-0834 / D / 06.27.13FR86 30.1AL’installation et l’entretien doivent être effectués par un installateur qualifi é. A. Mette

Page 107

!WARNINGLe 14” (355.8mm) au-dessus de l’ouverture de l’appareil doit être fi nis avec les matériaux incombustibles.Si vous désirez seulement une surfac

Page 108

W415-0834 / D / 06.27.13FR88 !AVERTISSEMENTRISQUE D’INCENDIE!AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CON-TACT A

Page 109 - D’ÉTANCHÉITÉ

W415-0834 / D / 06.27.13FR 89NE RIEN CONSTRUIRE DANS CETTE ZONE - CETTE ZONE DE 14 PO DE LARGEUR, CENTRÉE LE LONG DE L’AVANT DU FOYER, DOIT RESTÉE LIB

Page 110

W415-0834 / E / 06.13.13 9ENUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Min

Page 111

MUR ARRIÈRE DE L’ENCEINTE (INCLUANT DES MATÉRIAUX DE FINITION) ENCEINTEINTÉRIEUREENCEINTEEXTÉRIEURE46 ¾”(1187,5mm)73 ½”(1866,9mm)52”(1320,8mm)

Page 112

5.1 DÉGAGEMENTS MINIMAUX AUX ENCEINTES COMBUSTIBLESW415-0834 / D / 06.27.13FR 91IMPORTANT : Le LHD45 requiert une hauteur d’enceinte minimale de 56”

Page 113

W415-0834 / D / 06.27.13FR92 Le matériau de fi nition peut être fi xé directement au caisson lorsque cela s’avère pratique.COMBUSTIBLENON-COMBUSTIBLEHA

Page 114

W415-0834 / D / 06.27.13FR 935.2 INSTALLATION EN ALCÔVEAPPAREILZONE ENCASTRÉE OU ALCÔVENOTE : Les zones encastrées ou les alcôves au dessus de l&apos

Page 115 - SYMPTÔME PROBLÈME SOLUTIONS

Le dégagement d’une tablette combustible peut varier selon la profondeur de la tablette. Utilisez le graphique pour vous aider à déterminer le dégagem

Page 116

6.0 FINITIONS6.1 INSTALLATION/ENLÈVEMENT DE LA PORTEW415-0834 / D / 06.27.13FR 95!AVERTISSEMENTRISQUE D’INCENDIE!N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE

Page 117 - 14.0 GARANTIE

ƎPPƎPPA. Installez 4 piles AA (non fourni) dans le bloc-piles du boîtier fourni, notez la polarité des piles puis insérez-les comme

Page 118 - 15.0 HISTORIQUE D’ENTRETIEN

W415-0834 / D / 06.27.13FR 9774.2BÉparpillez soigneusement les braises vitrifi ées sur le plateau de manière uniforme. Assurez-vous qu’aucun morceau de

Page 119 - 16.0 NOTES

7.0 INSTALLATION DE LA SOUFFLERIE OPTIONELLE7.1 ACCÈS À LA SOUFFLERIE!AVERTISSEMENTFAITES ATTENTION DE NE PAS DÉCHIRER LE JOINT DÉTANCHÉTTÉ DU BRÛLEU

Page 120 - Autres produits Napoléon

W415-0834 / D / 06.27.13FR 99A. Enlevez la porte. Voir la section « ENLÈVEMENT ET INSTALLATION DE LA PORTE ».B. Retirez le plateau de braises/crista