W415-0834 / E / 06.13.13
33
EN
MANTEL DIMENSIONS
Ref Height Depth
A 25 5/16” (642.9mm)
B 6” (152.4mm) 2” (50.8mm)
C 8” (203.2mm) 4” (101.6mm)
D 10” (254mm) 6” (152.4mm)
E 12” (304.8mm) 8” (203.2mm)
E
D
C
B
A
TOP OF
APPLIANCE
(DOOR)
OPENING
BASE OF UNIT
MUST BE
NON-COMBUSTIBLE
FRONT OF
APPLIANCE
WARNING : Non-combustible facing material must not protrude more than 3/4” (19mm) from the top,
and/or sides of the appliance. If it does, it is considered a combustible mantel and must meet the
combustible mantel clearance requirements.
71.3A
3/4” (19mm)
FRONT OF
APPLIANCE
TOP VIEWSIDE VIEW
NON-COMBUSTIBLE
FACING MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
FINISH
MATERIAL
FINISH
MATERIAL
3/4” (19mm)
5.4 MINIMUM OVERHANG
5.5 NON-COMBUSTIBLE FACING MATERIAL
FROM TOP OF APPLIANCE OPENING
Ref Height Depth
A 25 5/16” (642.9mm)
B 0 2” (50.8mm)
C 2” (50.8mm) 6” (152.4mm)
D 4” (101.6mm) 10” (254mm)
NOTE: Projection must be non-combustible.