Napoleon-fireplaces Vector 45 - LHD45 User Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
W415-0834 / E / 06.13.13
41
EN
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996
national electrical code in the United States.
8.1 HARD WIRING CONNECTION
8.2 RECEPTACLE WIRING DIAGRAM
CABLE CONNECTOR
L1
L2
ELECTRICAL COVER
PRE-FINISHING
ACCESS PANEL
A. Remove the two screws that secure the junction box assembly to the outer shell on the left side of the
appliance and remove the junction box assembly.
B. Remove the one screw that secures the junction box to the junction box plate and slide off the clip.
C. Route the supply wire through the 7/8” (22.2mm) hole of the junction box plate with a box connector
(not supplied).
D. Connect the 120 volt supply wire to the receptacle as per the CSA C22.1 Canadian Electrical Code in
Canada or the ANSI/NFPA 70-1996 National Electrical Code in the United States.
E. Once the wiring is complete, re-install the junction box to the junction box plate and re-secure the
screw that was previously removed.
F. Re-install the junction box assembly by reversing step A.
NOTE: If the appliance is already installed inside the enclosure, you can access the junction box from
inside the appliance by removing the burner base assembly, see “BURNER REMOVAL” section and
“VALVE TRAIN REMOVAL” section.
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 119 120

Comments to this Manuals

No comments